Three-dimensional finite element analysis of full-arch implant-supported dental restorations: complete vs. segmented frameworks
Frontiers in Bioengineering and Biotechnology · 30.04.2026 · 14
DOI: 10.3389/fbioe.2026.1759007 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 30.04.2026. Verfasst von Eduardo Anitua und 2 weiteren Autor:innen. Beteiligte Einrichtung: Eduardo Anitua Foundation, Vitoria, Spain. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 53 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Purpose
Given the reported clinical advantages of segmented implant-supported mandibular frameworks, multiple segmentation patterns were evaluated and compared with a complete (one-piece) framework to determine their effects on peri-implant bone stress.
Methods
Thirteen cases were studied via 3-D finite element analysis (FEA), combining complete and segmented full-arch frameworks across different implant layouts. Screws were preloaded according to manufacturer recommendations. Cortical and trabecular bone were modeled as homogeneous, isotropic, linearly elastic materials, and a fully osseointegrated implant–bone interface (shared-node mesh) was assumed. A static vertical load of 200 N was applied in three separate load cases: first molar, first premolar, and bilateral incisors. The primary outcome was peak von Mises equivalent stress in the peri-implant bone surrounding each implant as a comparative indicator of mechanical demand.
Results
When the load fell between two splinted implants (e.g., lateral segment without cantilever), peri-implant bone stresses were similar for complete and segmented frameworks. Under premolar loading, the complete framework yielded the lowest stresses; segmenting with a mesial cantilever on the lateral segment approximately doubled stresses at the adjacent implant, while placing a distal cantilever on the central segment increased stresses near the anterior support by up to ∼7× versus the complete configuration. Eliminating cantilevers by moving support from 5 to 4 closely approached the complete framework. Incisor loading challenged the central span: supports at 3–3 produced markedly higher stresses than complete frameworks; shifting supports to 2–2 reduced stresses but did not match the complete design, whereas triangulating the central span (3–2–3) further lowered stresses and approached complete-framework levels.
Conclusion
Segmented frameworks are biomechanically viable provided segmentation avoids central-span cantilevers, preferentially places any unavoidable cantilever on a straight lateral segment, and—when feasible—adds an anterior support to triangulate the central span or eliminates cantilevers by advancing support distally. With a properly planned segmented framework, peri-implant bone stresses can remain close to those of complete frameworks under the loading conditions investigated.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Eduardo Anitua Foundation, Vitoria, Spain.
- R&D Department, Biotechnology Institute I mas D S.L., Vitoria, Spain.
Zitieren
APA
Anitua, E., Armentia, M., & Saracho, L. (2026). Three-dimensional finite element analysis of full-arch implant-supported dental restorations: complete vs. segmented frameworks. Frontiers in Bioengineering and Biotechnology, 14. https://doi.org/10.3389/fbioe.2026.1759007
Vancouver
Anitua E, Armentia M, Saracho L. Three-dimensional finite element analysis of full-arch implant-supported dental restorations: complete vs. segmented frameworks. Frontiers in Bioengineering and Biotechnology. 2026;14. doi:10.3389/fbioe.2026.1759007
BibTeX
@article{Anitua2026,
author = {Anitua, Eduardo and Armentia, Mikel and Saracho, Luis},
title = {Three-dimensional finite element analysis of full-arch implant-supported dental restorations: complete vs. segmented frameworks},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2026},
volume = {14},
doi = {10.3389/fbioe.2026.1759007}
}
EUVIMED