High-frame-rate ultrasound analysis of gastric peristalsis using the peristaltic analyzer: a pilot feasibility study
Frontiers in Bioengineering and Biotechnology · 19.12.2025 · 13
DOI: 10.3389/fbioe.2025.1715788 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 19.12.2025. Verfasst von Li Han und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ultrasound, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medici…. Die Arbeit wurde bisher 5-mal zitiert (Crossref) und nennt 18 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: National Natural Science Foundation of China.
Abstract (Originalsprache)
Background
Gastric peristalsis plays a pivotal role in regulating gastric emptying and digestive function. However, current clinical assessments of gastric motility primarily rely on invasive or low-temporal-resolution techniques, which fail to support dynamic, real-time evaluations.
Methods
We innovatively extended the Peristaltic Analyzer (PA)—a high-frame-rate ultrasound technology originally designed for endometrial wave analysis to the assessment of gastric peristalsis. Utilizing submicron displacement tracking and spatiotemporal vector analysis, we conducted real-time visualization and quantitative evaluation of gastric motility in 9 healthy volunteers.
Results
All participants completed image acquisition and peristaltic tracking. The detected peristaltic waves consistently propagated from the proximal to the distal stomach, with an average propagation speed of 1.99 ± 0.18 mm/s, propagation distance of 3.23 ± 0.33 cm, peristaltic intensity of 4.76 ± 1.52 (relative units), interval of 17.31 ± 0.86 s, and frequency of 3.53 ± 0.19 bpm. Waveforms appeared continuous and rhythmic, with uniform propagation direction and clear spatiotemporal profiles.
Conclusion
As the first application of the PA high-frame-rate peristaltic analysis technology to gastric motility assessment, this study demonstrates its strong potential as a non-invasive and real-time tool for early detection, quantitative monitoring, and clinical evaluation of functional gastrointestinal disorders. PA exhibited superior performance in motion detection, directional analysis, and fine-scale displacement measurement. These capabilities highlight its potential as a novel tool for early identification and longitudinal monitoring of functional gastrointestinal disorders, postoperative gastric dysmotility, and diabetic gastroparesis, offering substantial clinical translational value and applicability.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Ultrasound, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, School of Medicine, University of Electronic Science and Technology of China, Chengdu,…
- Department of Ultrasound, Sichuan Clinical Research Center for Cancer, Sichuan Cancer Hospital and Institute, Sichuan Cancer Center, University of Electronic Science and Technology of China, Chengdu, China.
Förderung
- National Natural Science Foundation of China
Zitieren
APA
Han, L., Li, T., Zhuang, M., Li, Y., He, C., Zhang, Z., & Lu, M. (2025). High-frame-rate ultrasound analysis of gastric peristalsis using the peristaltic analyzer: a pilot feasibility study. Frontiers in Bioengineering and Biotechnology, 13. https://doi.org/10.3389/fbioe.2025.1715788
Vancouver
Han L, Li T, Zhuang M, Li Y, He C, Zhang Z, et al. High-frame-rate ultrasound analysis of gastric peristalsis using the peristaltic analyzer: a pilot feasibility study. Frontiers in Bioengineering and Biotechnology. 2025;13. doi:10.3389/fbioe.2025.1715788
BibTeX
@article{Han2025,
author = {Han, Li and Li, Tingting and Zhuang, Min and Li, Yuan and He, Chuanshi and Zhang, Zijian and Lu, Man},
title = {High-frame-rate ultrasound analysis of gastric peristalsis using the peristaltic analyzer: a pilot feasibility study},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2025},
volume = {13},
doi = {10.3389/fbioe.2025.1715788}
}
EUVIMED