Is an additional cannulated screw necessary for unstable femoral neck fractures with comminuted posteromedial cortex by femoral neck system (FNS) fixation? a biomechanical and clinical study
Frontiers in Bioengineering and Biotechnology · 14.11.2025 · 13
DOI: 10.3389/fbioe.2025.1658728 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 14.11.2025. Verfasst von Jixing Fan und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Orthopedics, Peking University Third Hospital, Beijing, China. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 39 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Background
The purpose of this study was to explore the biomechanical property and clinical efficacy of femoral neck system (FNS) with an additional cannulated screws (CS) in the treatment of unstable femoral neck fracture (FNFs) with comminuted posteromedial cortex.
Methods
Firstly, we developed a model of Pauwels type III FNF with comminuted posteromedial cortex for the finite element analysis (FEA). Two experimental models were set up: the FNS model and the FNS + CS model. The von Mises stress on the proximal femur, implant and the total displacement of the device components were evaluated for both FNS and FNS + CS models. Secondly, we retrospectively included the cases of vertical FNFs with comminuted posteromedial cortex by FNS or FNS + CS fixation in our hospital from January 2020 to December 2023. In this study, demographic information, femoral neck shortening, Harris score of hip joint function, and postoperative complications were collected and compared.
Results
The FEA results showed similar peak von Mises stress of the implant in two models and the additional CS could share the stress concentration with the FNS in the FNS + CS model. In terms of proximal femur, the maximum von Mises stress of the FNS model increased by 15.43% when compared with the FNS + CS model, and the magnitude of these two models were 83.02 MPa and 71.92 MPa, respectively. Furthermore, the maximum displacement in the FNS + CS model was much smaller than that in the FNS model. Clinically, the femoral neck shortening distance was significantly longer in the FNS group (5.62 ± 3.32 mm) than that in the FNS + CS group (3.49 ± 2.01 mm) ( p = 0.027). Furthermore, the incidence of moderate to severe shortening (≥5 mm) was significantly higher in the FNS group compared with the FNS + CS group ( p = 0.039). Moreover, the patients in the FNS + CS group had a higher Harris score than patients in the FNS group (91.97 vs. 88.56, p = 0.003).
Conclusion
Compared to the FNS alone, the FEA results showed that the FNS + CS had better biomechanical properties and the clinical results showed that the FNS + CS had a shorter femoral neck shortening and higher Harris score in treating unstable FNFs with comminuted posteromedial cortex.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Orthopedics, Peking University Third Hospital, Beijing, China.
- Engineering Research Center of Bone and Joint Precision Medicine, Ministry of Education, Beijing, China.
Zitieren
APA
Fan, J., Hao, Y., Cao, Y., Cui, Z., Lv, Y., & Zhou, F. (2025). Is an additional cannulated screw necessary for unstable femoral neck fractures with comminuted posteromedial cortex by femoral neck system (FNS) fixation? a biomechanical and clinical study. Frontiers in Bioengineering and Biotechnology, 13. https://doi.org/10.3389/fbioe.2025.1658728
Vancouver
Fan J, Hao Y, Cao Y, Cui Z, Lv Y, Zhou F. Is an additional cannulated screw necessary for unstable femoral neck fractures with comminuted posteromedial cortex by femoral neck system (FNS) fixation? a biomechanical and clinical study. Frontiers in Bioengineering and Biotechnology. 2025;13. doi:10.3389/fbioe.2025.1658728
BibTeX
@article{Fan2025,
author = {Fan, Jixing and Hao, Youliang and Cao, Yuan and Cui, Zengzhen and Lv, Yang and Zhou, Fang},
title = {Is an additional cannulated screw necessary for unstable femoral neck fractures with comminuted posteromedial cortex by femoral neck system (FNS) fixation? a biomechanical and clinical study},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2025},
volume = {13},
doi = {10.3389/fbioe.2025.1658728}
}
EUVIMED