EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

The effects of different carbon-fiber plate shapes in shoes on lower limb biomechanics following running-induced fatigue

Yufan Xu, Chengyuan Zhu, Yufei Fang, Zhenghui Lu, Yang Song, Chen Hu, Dong Sun, Yaodong Gu

Frontiers in Bioengineering and Biotechnology · 11.02.2025 · 13

DOI: 10.3389/fbioe.2025.1539976 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 11.02.2025. Verfasst von Yufan Xu und 7 weiteren Autor:innen. Beteiligte Einrichtung: Faculty of Sports Science, Ningbo University, Ningbo, China. Die Arbeit wurde bisher 14-mal zitiert (Crossref) und nennt 62 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Different shapes of carbon-fiber plates (CFPs) are likely to affect lower limb biomechanics, particularly under conditions of running-induced fatigue, and potentially impact runners’ performance and risk of injury. However, no studies have yet elucidated the precise effects of CFP shapes on the lower limb biomechanical characteristics subsequent to running-induced fatigue. The purpose of this study was to investigate the effects of different CFP shapes in running shoes on the lower limb biomechanics of runners following running-induced fatigue. 12 male runners (aged 21.8 ± 1.3 years, mass 59.1 ± 4.1 kg, height 168.9 ± 2.2 cm, weekly running distance 68.8 ± 5.5 km/week) were recruited for this study. Two-way repeated measures ANOVA was used to compare kinematic and kinetic data, while SPM (Statistical Parametric Mapping) was used to assess the activation levels of lower limb muscles. Compared to wearing flat CFP shoes (“Flat”), wearing curved CFP shoes (“Curve”) resulted in a significant reduction in the hip (p = 0.034) and knee contact angle (p < 0.000), as well as a significant decrease in the hip flexion moment (p = 0.008). The activation level of the tibialis anterior (TA) was significantly higher when wearing “Curve” in pre-fatigue compared to “Flat”, whereas the opposite was observed post-fatigue. The curved CFP altered the bending angle of the forefoot, thereby significantly reducing the joint angles and joint moments of the hip and knee.

Schlagwörter

Stichwörter der Autor:innen

carbon-fiber plate (CFP)injurylower limb biomechanicsrunning performancerunning-induced fatigue

Autor:innen und Institutionen

  • Faculty of Sports Science, Ningbo University, Ningbo, China.
  • Department of Radiology, Ningbo No. 2 Hospital, Ningbo, China.
  • Faculty of Engineering, University of Pannonia, Veszprem, Hungary.
  • Department of Material Science and Technology, Audi Hungaria Faculty of Automotive Engineering, Széchenyi István University, Győr, Hungary.
  • Department of Biomedical Engineering, Faculty of Engineering, The Hong Kong Polytechnic University, Kowloon, Hong Kong SAR, China.

Zitieren

APA

Xu, Y., Zhu, C., Fang, Y., Lu, Z., Song, Y., Hu, C., Sun, D., & Gu, Y. (2025). The effects of different carbon-fiber plate shapes in shoes on lower limb biomechanics following running-induced fatigue. Frontiers in Bioengineering and Biotechnology, 13. https://doi.org/10.3389/fbioe.2025.1539976

Vancouver

Xu Y, Zhu C, Fang Y, Lu Z, Song Y, Hu C, et al. The effects of different carbon-fiber plate shapes in shoes on lower limb biomechanics following running-induced fatigue. Frontiers in Bioengineering and Biotechnology. 2025;13. doi:10.3389/fbioe.2025.1539976

BibTeX
@article{Xu2025,
  author = {Xu, Yufan and Zhu, Chengyuan and Fang, Yufei and Lu, Zhenghui and Song, Yang and Hu, Chen and Sun, Dong and Gu, Yaodong},
  title = {The effects of different carbon-fiber plate shapes in shoes on lower limb biomechanics following running-induced fatigue},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2025},
  volume = {13},
  doi = {10.3389/fbioe.2025.1539976}
}
Kostenlos starten →