EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Non-contact tracking of shoulder bones using ultrasound and stereophotogrammetry

Ahmed Sewify, Maxence Lavaill, Dermot O'Rourke, Maria Antico, Peter Pivonka, Davide Fontanarosa, Saulo Martelli

Frontiers in Bioengineering and Biotechnology · 06.02.2025 · 13

DOI: 10.3389/fbioe.2025.1514568 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 06.02.2025. Verfasst von Ahmed Sewify und 6 weiteren Autor:innen. Beteiligte Einrichtung: School of Clinical Sciences, Queensland University of Technology, Gardens Point Campus, Brisbane, QLD, Australia. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 32 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Australian Research Council.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

We explored the integration of 3D ultrasound (US) imaging with motion capture technology for non-invasively tracking bones of the shoulder district during normal activity. Our study aimed to demonstrate ex-vivo the proposed 3D US method’s feasibility and accuracy of tracking shoulder bones in a controlled cadaveric shoulder positioned in various arm elevations (low, mid and high).

Method

We registered previously acquired full bone shapes to spatially small bony surface patches segmented from 3D US. The bone registration approach used was based on in silico analyses that investigated the effects of different — 1) registration algorithms (Iterative-Closest-Point–ICP, and Coherent Point Drift–CPD) and 2) initial estimate levels of the bone model pose relative to the targeted final bone pose—on the overall registration efficiency and accuracy in a controlled environment.

Results

CPD provided the highest accuracy in the simulation at the cost of 8x longer computation compared to ICP. The RMSE errors were <1 mm for the humerus and scapula at all elevations. Ex-vivo , the CPD registration errors were (Humerus = 2 mm and Scapula = 13.9 mm) (Humerus = 7.2 mm and Scapula = 16.8 mm) and (Humerus = 14.28 mm and Scapula = 27.5 mm), for low, medium and high elevations respectively.

Conclusion

In summary, we demonstrated the feasibility and accuracy of tracking shoulder bones with 3D US in a simulation and a cadaveric experiment. We discovered that CPD may be a more suitable registration method for the task than ICP. We also discussed that 3D US with motion capture technology is very promising for dynamic bone tracking, but the US technology may not be ready for the task yet.

Schlagwörter

Stichwörter der Autor:innen

3D-ultrasoundShoulderbone registrationbone trackingex-vivoiterative closest point (ICP) algorithmstereophotogrammetryultrasound

Autor:innen und Institutionen

  • School of Clinical Sciences, Queensland University of Technology, Gardens Point Campus, Brisbane, QLD, Australia.
  • Centre for Biomedical Technologies, Queensland University of Technology, Brisbane, QLD, Australia.
  • School of Mechanical Medical and Process Engineering, Faculty of Engineering, Queensland University of Technology, Gardens Point Campus, Brisbane, QLD, Australia.
  • Australian e-Health Research Centre, The Commonwealth Scientific and Industrial Research Organisation (CSIRO), Brisbane, QLD, Australia.

Förderung

  • Australian Research Council

Zitieren

APA

Sewify, A., Lavaill, M., O'Rourke, D., Antico, M., Pivonka, P., Fontanarosa, D., & Martelli, S. (2025). Non-contact tracking of shoulder bones using ultrasound and stereophotogrammetry. Frontiers in Bioengineering and Biotechnology, 13. https://doi.org/10.3389/fbioe.2025.1514568

Vancouver

Sewify A, Lavaill M, O'Rourke D, Antico M, Pivonka P, Fontanarosa D, et al. Non-contact tracking of shoulder bones using ultrasound and stereophotogrammetry. Frontiers in Bioengineering and Biotechnology. 2025;13. doi:10.3389/fbioe.2025.1514568

BibTeX
@article{Sewify2025,
  author = {Sewify, Ahmed and Lavaill, Maxence and O'Rourke, Dermot and Antico, Maria and Pivonka, Peter and Fontanarosa, Davide and Martelli, Saulo},
  title = {Non-contact tracking of shoulder bones using ultrasound and stereophotogrammetry},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2025},
  volume = {13},
  doi = {10.3389/fbioe.2025.1514568}
}