Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 28.11.2024. Verfasst von Juan Li und 3 weiteren Autor:innen. Beteiligte Einrichtung: Shaanxi Provincial Land Engineering Construction Group, Key Laboratory of Degraded and Unused Land Consolidation Engineering, Ministry of Natural Res…. Die Arbeit wurde bisher 9-mal zitiert (Crossref) und nennt 51 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Reducing total nitrogen (TN) presents a significant challenge for numerous wastewater treatment facilities. In order to address this issue, the current study employed a biological aerated filter for the treatment of wastewater containing low nitrogen concentrations. Both lab-scale and pilot-scale biofilters were constructed to investigate the denitrification performance and maximum denitrification load. The findings indicated that the anaerobic denitrification process of established biofilm adhered to pseudo-first-order kinetics. The results of batch testing and continuous-flow experiments confirmed that the minimum hydraulic retention time (HRT) required for mature biofilm was determined to be 0.5 h. The optimal operating parameters were found to be as follows: influent NO 3 − -N concentration of 25 mg/L, HRT of 0.5 h, resulting in effluent TN levels below 1 mg/L. Under these conditions, the denitrifying load for the lab-scale I-BAF system was calculated to be 1.26 kg (TN)/(m 3 ·d). Furthermore, it was observed that the maximum denitrifying load could reach 2.2 kg (TN)/(m 3 ·d) when the influent NO 3 − -N concentration was increased to 50 mg/L while maintaining an HRT of 0.5 h. For the mature biofilter, the appropriate HRT ranged from 2 h to 0.5 h. Microbial diversity analysis revealed that the genus Enterobacter was dominant in all denitrification systems, followed by Comamonas and Rhodococcus . The operational parameters described in the paper could be recommended for a full-scale wastewater treatment facility.

Schlagwörter

Stichwörter der Autor:innen

advanced wastewater treatmentdenitrification loadimmobilized biological aerated filtermicrobial communitytotal nitrogen removal

Autor:innen und Institutionen

  • Shaanxi Provincial Land Engineering Construction Group, Key Laboratory of Degraded and Unused Land Consolidation Engineering, Ministry of Natural Resources, Xi'an, China.
  • Shaanxi Engineering Research Center of Land Consolidation, Shaanxi Provincial Land Consolidation Engineering Technology Research Center, Xi'an, China.
  • Kweichow Moutai Winery (Group) Health Wine Co., LTD., Renhuai, China.
  • School of Environmental Science and Engineering, Suzhou University of Science and Technology, Suzhou, China.

Zitieren

APA

Li, J., Niu, Z., Li, L., & Zhou, S. (2024). Optimizing nitrogen removal in advanced wastewater treatment using biological aerated filters. Frontiers in Bioengineering and Biotechnology, 12. https://doi.org/10.3389/fbioe.2024.1463544

Vancouver

Li J, Niu Z, Li L, Zhou S. Optimizing nitrogen removal in advanced wastewater treatment using biological aerated filters. Frontiers in Bioengineering and Biotechnology. 2024;12. doi:10.3389/fbioe.2024.1463544

BibTeX
@article{Li2024,
  author = {Li, Juan and Niu, Ziru and Li, Lei and Zhou, Shuting},
  title = {Optimizing nitrogen removal in advanced wastewater treatment using biological aerated filters},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2024},
  volume = {12},
  doi = {10.3389/fbioe.2024.1463544}
}
Kostenlos starten →