EUVIMEDEUVIMED entdecken
ÜbersichtsarbeitOpen Access · CC BY 4.0

Deep learning and remote photoplethysmography powered advancements in contactless physiological measurement

Wei Chen, Zhe Yi, Lincoln Jian Rong Lim, Rebecca Qian Ru Lim, Aijie Zhang, Zhen Qian, Jiaxing Huang, Jia He, Bo Liu

Frontiers in Bioengineering and Biotechnology · 17.07.2024 · 12

DOI: 10.3389/fbioe.2024.1420100 ↗

Kurz gefasst

Übersichtsarbeit in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 17.07.2024. Verfasst von Wei Chen und 8 weiteren Autor:innen. Beteiligte Einrichtung: Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China. Die Arbeit wurde bisher 41-mal zitiert (Crossref) und nennt 194 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

In recent decades, there has been ongoing development in the application of computer vision (CV) in the medical field. As conventional contact-based physiological measurement techniques often restrict a patient’s mobility in the clinical environment, the ability to achieve continuous, comfortable and convenient monitoring is thus a topic of interest to researchers. One type of CV application is remote imaging photoplethysmography (rPPG), which can predict vital signs using a video or image. While contactless physiological measurement techniques have an excellent application prospect, the lack of uniformity or standardization of contactless vital monitoring methods limits their application in remote healthcare/telehealth settings. Several methods have been developed to improve this limitation and solve the heterogeneity of video signals caused by movement, lighting, and equipment. The fundamental algorithms include traditional algorithms with optimization and developing deep learning (DL) algorithms. This article aims to provide an in-depth review of current Artificial Intelligence (AI) methods using CV and DL in contactless physiological measurement and a comprehensive summary of the latest development of contactless measurement techniques for skin perfusion, respiratory rate, blood oxygen saturation, heart rate, heart rate variability, and blood pressure.

Schlagwörter

Stichwörter der Autor:innen

artificial intelligencecomputer visiondeep learningphysiological measurementrPPG

Autor:innen und Institutionen

  • Department of Hand Surgery, Beijing Jishuitan Hospital, Capital Medical University, Beijing, China.
  • Department of Medical Imaging, Western Health, Footscray Hospital, Footscray, VIC, Australia.
  • Department of Surgery, The University of Melbourne, Melbourne, VIC, Australia.
  • Department of Hand & Reconstructive Microsurgery, Singapore General Hospital, Singapore, Singapore.
  • Institute of Intelligent Diagnostics, Beijing United-Imaging Research Institute of Intelligent Imaging, Beijing, China.
  • Institute of Automation, Chinese Academy of Sciences, Beijing, China.

Zitieren

APA

Chen, W., Yi, Z., Lim, L. J. R., Lim, R. Q. R., Zhang, A., Qian, Z., Huang, J., He, J., & Liu, B. (2024). Deep learning and remote photoplethysmography powered advancements in contactless physiological measurement. Frontiers in Bioengineering and Biotechnology, 12. https://doi.org/10.3389/fbioe.2024.1420100

Vancouver

Chen W, Yi Z, Lim LJR, Lim RQR, Zhang A, Qian Z, et al. Deep learning and remote photoplethysmography powered advancements in contactless physiological measurement. Frontiers in Bioengineering and Biotechnology. 2024;12. doi:10.3389/fbioe.2024.1420100

BibTeX
@article{Chen2024,
  author = {Chen, Wei and Yi, Zhe and Lim, Lincoln Jian Rong and Lim, Rebecca Qian Ru and Zhang, Aijie and Qian, Zhen and Huang, Jiaxing and He, Jia and Liu, Bo},
  title = {Deep learning and remote photoplethysmography powered advancements in contactless physiological measurement},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2024},
  volume = {12},
  doi = {10.3389/fbioe.2024.1420100}
}
Kostenlos starten →