A novel non-invasive electromagnetic extendable intercalary endoprosthesis: a proof-of-concept study

Siyi Huang, Jiake Yang, Xinyu Li, Xiaodong Tang, Tao Ji

Frontiers in Bioengineering and Biotechnology · 18.07.2024 · 12

DOI: 10.3389/fbioe.2024.1400428 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 18.07.2024. Verfasst von Siyi Huang und 4 weiteren Autor:innen. Beteiligte Einrichtung: Musculoskeletal Tumor Center, Peking University People's Hospital, Beijing, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 30 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Femur and tibia are the most commonly affected sites for primary malignant bone tumors in children. The wide resection of the tumor frequently requires the physis to be resected. The normal growth of the unaffected limb will result in a significant limb length discrepancy at skeletal maturity. To compensate for this resulting LLD, different generations of extendible endoprostheses have been developed. Non-invasive extendable prostheses eliminate the need for surgical procedures and general anesthesia, enabling gradual and painless lengthening. Currently available non-invasive extendable prostheses focus on joint reconstruction, and no case series analysis of intercalary non-invasive extendable prosthesis has been reported. Therefore, we have designed a novel non-invasive electromagnetic extendable intercalary endoprosthesis.

Methods

In vitro mechanical experiments and in vivo animal experiments were conducted.

Results

In vitro experiments have confirmed that the prosthetics can extend at a constant rate, increasing by 4.4 mm every 10 min. The average maximum extension force during prosthetic elongation can reach 1306N. In animal in vivo experiments, the extension process is smooth and non-invasive, and the sheep is in a comfortable state.

Discussion

The in vitro and in vivo animal studies provide evidence to support the extension reliability, laying the foundation for future large-scale validation experiments.

Schlagwörter

Stichwörter der Autor:innen

electromagnetic driveextendable endoprosthesisintercalary endoprosthesislimb length discrepancynon-invasive extendable endoprothesis

Autor:innen und Institutionen

  • Musculoskeletal Tumor Center, Peking University People's Hospital, Beijing, China.
  • Beijing Key Laboratory of Musculoskeletal Tumor, Beijing, China.
  • Beijing AK Medical Co., Ltd., Beijing, China.

Zitieren

APA

Huang, S., Yang, J., Li, X., Tang, X., & Ji, T. (2024). A novel non-invasive electromagnetic extendable intercalary endoprosthesis: a proof-of-concept study. Frontiers in Bioengineering and Biotechnology, 12. https://doi.org/10.3389/fbioe.2024.1400428

Vancouver

Huang S, Yang J, Li X, Tang X, Ji T. A novel non-invasive electromagnetic extendable intercalary endoprosthesis: a proof-of-concept study. Frontiers in Bioengineering and Biotechnology. 2024;12. doi:10.3389/fbioe.2024.1400428

BibTeX
@article{Huang2024,
  author = {Huang, Siyi and Yang, Jiake and Li, Xinyu and Tang, Xiaodong and Ji, Tao},
  title = {A novel non-invasive electromagnetic extendable intercalary endoprosthesis: a proof-of-concept study},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2024},
  volume = {12},
  doi = {10.3389/fbioe.2024.1400428}
}
Kostenlos starten →