Embedded-deep-learning-based sample-to-answer device for on-site malaria diagnosis
Frontiers in Bioengineering and Biotechnology · 19.07.2024 · 12
DOI: 10.3389/fbioe.2024.1392269 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 19.07.2024. Verfasst von Chae Yun Bae und 16 weiteren Autor:innen. Beteiligte Einrichtung: Noul Co., Ltd., Yongin-si, Republic of Korea. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Improvements in digital microscopy are critical for the development of a malaria diagnosis method that is accurate at the cellular level and exhibits satisfactory clinical performance. Digital microscopy can be enhanced by improving deep learning algorithms and achieving consistent staining results. In this study, a novel miLab™ device incorporating the solid hydrogel staining method was proposed for consistent blood film preparation, eliminating the use of complex equipment and liquid reagent maintenance. The miLab™ ensures consistent, high-quality, and reproducible blood films across various hematocrits by leveraging deformable staining patches. Embedded-deep-learning-enabled miLab™ was utilized to detect and classify malarial parasites from autofocused images of stained blood cells using an internal optical system. The results of this method were consistent with manual microscopy images. This method not only minimizes human error but also facilitates remote assistance and review by experts through digital image transmission. This method can set a new paradigm for on-site malaria diagnosis. The miLab™ algorithm for malaria detection achieved a total accuracy of 98.86% for infected red blood cell (RBC) classification. Clinical validation performed in Malawi demonstrated an overall percent agreement of 92.21%. Based on these results, miLab™ can become a reliable and efficient tool for decentralized malaria diagnosis.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Noul Co., Ltd., Yongin-si, Republic of Korea.
- Wezi Medical Centre, Mzuzu, Malawi.
- Department of Medical Parasitology and Infection Biology, Swiss Tropical and Public Health Institute, Allschwil, Switzerland.
- University of Basel, Basel, Switzerland.
- Korea Centers for Disease Control and Preventions (KCDC), Department of Malaria and Parasitic Diseases, Cheongju-si, Republic of Korea.
Zitieren
APA
Bae, C. Y., Shin, Y. M., Kim, M., Song, Y., Lee, H. J., Kim, K. H., Lee, H. W., Kim, Y. J., Kanyemba, C., Lungu, D. K., Kang, B. I., Han, S., Beck, H. P., Cho, S. H., Woo, B. M., Lim, C. Y., & Choi, K. H. (2024). Embedded-deep-learning-based sample-to-answer device for on-site malaria diagnosis. Frontiers in Bioengineering and Biotechnology, 12. https://doi.org/10.3389/fbioe.2024.1392269
Vancouver
Bae CY, Shin YM, Kim M, Song Y, Lee HJ, Kim KH, et al. Embedded-deep-learning-based sample-to-answer device for on-site malaria diagnosis. Frontiers in Bioengineering and Biotechnology. 2024;12. doi:10.3389/fbioe.2024.1392269
BibTeX
@article{Bae2024,
author = {Bae, Chae Yun and Shin, Young Min and Kim, Mijin and Song, Younghoon and Lee, Hong Jong and Kim, Kyung Hwan and Lee, Hong Woo and Kim, Yong Jun and Kanyemba, Creto and Lungu, Douglas K and Kang, Byeong-Il and Han, Seunghee and Beck, Hans-Peter and Cho, Shin-Hyeong and Woo, Bo Mee and Lim, Chan Yang and Choi, Kyung-Hak},
title = {Embedded-deep-learning-based sample-to-answer device for on-site malaria diagnosis},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2024},
volume = {12},
doi = {10.3389/fbioe.2024.1392269}
}