Bioprocess monitoring applications of an innovative ATR-FTIR spectroscopy platform

Loren Christie, Samantha Rutherford, David S Palmer, Matthew J Baker, Holly J Butler

Frontiers in Bioengineering and Biotechnology · 28.05.2024 · 12

DOI: 10.3389/fbioe.2024.1349473 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 28.05.2024. Verfasst von Loren Christie und 4 weiteren Autor:innen. Beteiligte Einrichtung: Dxcover Ltd., Glasgow, United Kingdom. Die Arbeit wurde bisher 16-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Pharmaceutical manufacturing is reliant upon bioprocessing approaches to generate the range of therapeutic products that are available today. The high cost of production, susceptibility to process failure, and requirement to achieve consistent, high-quality product means that process monitoring is paramount during manufacturing. Process analytic technologies (PAT) are key to ensuring high quality product is produced at all stages of development. Spectroscopy-based technologies are well suited as PAT approaches as they are non-destructive and require minimum sample preparation. This study explored the use of a novel attenuated total reflection Fourier transform infrared (ATR-FTIR) spectroscopy platform, which utilises disposable internal reflection elements (IREs), as a method of upstream bioprocess monitoring. The platform was used to characterise organism health and to quantify cellular metabolites in growth media using quantification models to predict glucose and lactic acid levels both singularly and combined. Separation of the healthy and nutrient deficient cells within PC space was clearly apparent, indicating this technique could be used to characterise these classes. For the metabolite quantification, the binary models yielded R 2 values of 0.969 for glucose, 0.976 for lactic acid. When quantifying the metabolites in tandem using a multi-output partial least squares model, the corresponding R 2 value was 0.980. This initial study highlights the suitability of the platform for bioprocess monitoring and paves the way for future in-line developments.

Schlagwörter

Stichwörter der Autor:innen

bioprocess monitoringbioprocessingfourier transform infrared spectroscopy (FTIR)metabolite quantificationprocess analytical technology (PAT)

Autor:innen und Institutionen

  • Dxcover Ltd., Glasgow, United Kingdom.
  • Pure and Applied Chemistry, University of Strathclyde, Glasgow, United Kingdom.
  • School of Medicine and Dentistry, University of Central Lancashire, Preston, United Kingdom.

Zitieren

APA

Christie, L., Rutherford, S., Palmer, D. S., Baker, M. J., & Butler, H. J. (2024). Bioprocess monitoring applications of an innovative ATR-FTIR spectroscopy platform. Frontiers in Bioengineering and Biotechnology, 12. https://doi.org/10.3389/fbioe.2024.1349473

Vancouver

Christie L, Rutherford S, Palmer DS, Baker MJ, Butler HJ. Bioprocess monitoring applications of an innovative ATR-FTIR spectroscopy platform. Frontiers in Bioengineering and Biotechnology. 2024;12. doi:10.3389/fbioe.2024.1349473

BibTeX
@article{Christie2024,
  author = {Christie, Loren and Rutherford, Samantha and Palmer, David S and Baker, Matthew J and Butler, Holly J},
  title = {Bioprocess monitoring applications of an innovative ATR-FTIR spectroscopy platform},
  journal = {Frontiers in Bioengineering and Biotechnology},
  year = {2024},
  volume = {12},
  doi = {10.3389/fbioe.2024.1349473}
}
Kostenlos starten →