Comparative experimental study of the biomechanical properties of retrograde tibial nailing and distal tibia plate in distal tibia fracture
Frontiers in Bioengineering and Biotechnology · 20.02.2024 · 12
DOI: 10.3389/fbioe.2024.1322043 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 20.02.2024. Verfasst von Xuping Lin und 6 weiteren Autor:innen. Beteiligte Einrichtung: Department of Spinal Surgery, Longyan First Affiliated Hospital of Fujian Medical University, Longyan, China. Die Arbeit wurde bisher 2-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Objective
A biomechanical comparative analysis was conducted to evaluate the retrograde tibial nailing (RTN) and distal tibia plate techniques for the treatment of distal tibia fractures.
Methods
Fourteen fresh adult tibia specimens were selected, consisting of seven males and seven females aged 34–55 years. The specimens were randomly divided into two groups (Group A and Group B) using a numerical table method, with seven specimens in each group. Group A underwent internal fixation of distal tibial fractures using RTN, while Group B received internal fixation using a plate. The axial compression properties of the specimens were tested in the neutral positions under pressures of 100, 200, 300, 400, and 500 N. Additionally, the torsional resistance of the two groups was assessed by subjecting the specimens to torques of 1.0, 2.0, 3.0, 4.0, and 5.0 N m.
Results
At pressures of 400 and 500 N, the axial compression displacement in Group A (1.11 ± 0.06, 1.24 ± 0.05) mm was significantly smaller than that in Group B (1.21 ± 0.08, 1.37 ± 0.11) mm ( p = 0.023, 0.019). Moreover, at a pressure of 500 N, the axial compression stiffness in Group A (389.24 ± 17.79) N/mm was significantly higher than that of the control group (362.37 ± 14.44) N/mm ( p = 0.010). When subjected to torques of 4 and 5 N m, the torsion angle in Group A (2.97° ± 0.23°, 3.41° ± 0.17°) was significantly smaller compared to Group B (3.31° ± 0.28°, 3.76° ± 0.20°) ( p = 0.035, 0.004). Furthermore, at a torque of 5 N m, the torsional stiffness in Group A (1.48 ± 0.07) N m/° was significantly higher than that in Group B (1.36 ± 0.06) N·m/° ( p = 0.003).
Conclusion
The results obtained from the study demonstrate that the biomechanical performance of RTN outperforms that of the distal tibial plate, providing valuable biomechanical data to support the clinical implementation of RTN.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Spinal Surgery, Longyan First Affiliated Hospital of Fujian Medical University, Longyan, China.
- Department of Orthopedic Surgery, The Affiliated Dongnan Hospital of Xiamen University, Zhangzhou, China.
- Shengli Clinical Medical College of Fujian Medical University, Fuzhou, China.
Zitieren
APA
Lin, X., Zhang, C., Yang, Y., Yang, W., Wang, X., Lu, H., & Liu, Q. (2024). Comparative experimental study of the biomechanical properties of retrograde tibial nailing and distal tibia plate in distal tibia fracture. Frontiers in Bioengineering and Biotechnology, 12. https://doi.org/10.3389/fbioe.2024.1322043
Vancouver
Lin X, Zhang C, Yang Y, Yang W, Wang X, Lu H, et al. Comparative experimental study of the biomechanical properties of retrograde tibial nailing and distal tibia plate in distal tibia fracture. Frontiers in Bioengineering and Biotechnology. 2024;12. doi:10.3389/fbioe.2024.1322043
BibTeX
@article{Lin2024,
author = {Lin, Xuping and Zhang, Cong and Yang, Yanfang and Yang, Wencheng and Wang, Xiaomeng and Lu, Haichuan and Liu, Qingjun},
title = {Comparative experimental study of the biomechanical properties of retrograde tibial nailing and distal tibia plate in distal tibia fracture},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2024},
volume = {12},
doi = {10.3389/fbioe.2024.1322043}
}
EUVIMED