Comparison of biomechanical parameters in lower limb joints of stroke patients according to conventional evaluation scores during level walking
Frontiers in Bioengineering and Biotechnology · 26.02.2024 · 12
DOI: 10.3389/fbioe.2024.1320337 ↗Kurz gefasst
Fachartikel in der Zeitschrift Frontiers in Bioengineering and Biotechnology, online erschienen am 26.02.2024. Verfasst von HyeongMin Jeon und 6 weiteren Autor:innen. Beteiligte Einrichtung: Digital Therapeutics Research Team, CHA Bundang Medical Center, CHA Future Medicine Research Institute, CHA University School of Medicine, Seongnam, …. Die Arbeit wurde bisher 6-mal zitiert (Crossref) und nennt 54 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Themen: Schlaganfall
Abstract (Originalsprache)
Objective
Patients with chronic stroke capable of independent gait were classified into functional ambulation category (FAC) 4 or 5, and the kinetic and kinematic data on their lower limb joints on the affected and unaffected sides were compared with that of healthy individuals. Finally, the qualitative changes in the gait of patients with stroke were investigated based on the differences in FAC scores.
Methods
Twelve healthy participants and 19 patients with stroke capable of independent gait were included. The three-dimensional (3D) motion analysis and conventional assessment were conducted for all patients with stroke.
Results
The FAC 5 group exhibited a larger range of motion (ROM) than the FAC 4 group in knee and hip joints on the affected side and only in the hip on the unaffected side. In the FAC 5 group, ROM differences in the healthy group on either the affected or unaffected side were absent. The peak of the hip flexion moment on the affected side in both the FAC 4 and 5 groups was smaller than that in the healthy group and in the FAC 4 group on the unaffected side. The absorption power minimum on the affected side was smaller only in the FAC 4 group than that in the healthy group and was larger in the FAC 5 group than that in the FAC 4 group. On the unaffected side, the absorption power minimum was smaller only in the FAC 4 group than that in the healthy group.
Conclusion
Functional differences in gait were found in patients classified based on conventional evaluation capable of independent gait after post-stroke rehabilitation. Patients may not exhibit complete recovery in the kinetic indices even if they are judged to be normal in the conventional evaluation, and the kinematic gait indices indicate recovery. Evaluating kinetic indices in addition to kinematic indices is necessary, and joint power may be an especially useful index.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Digital Therapeutics Research Team, CHA Bundang Medical Center, CHA Future Medicine Research Institute, CHA University School of Medicine, Seongnam, Republic of Korea.
- Department of Rehabilitation Medicine, CHA Bundang Medical Center, CHA University School of Medicine, Seongnam, Republic of Korea.
Zitieren
APA
Jeon, H., Chung, E. H., Bak, S. Y., Kim, H., Shin, S., Baek, H., & Kim, M. (2024). Comparison of biomechanical parameters in lower limb joints of stroke patients according to conventional evaluation scores during level walking. Frontiers in Bioengineering and Biotechnology, 12. https://doi.org/10.3389/fbioe.2024.1320337
Vancouver
Jeon H, Chung EH, Bak SY, Kim H, Shin S, Baek H, et al. Comparison of biomechanical parameters in lower limb joints of stroke patients according to conventional evaluation scores during level walking. Frontiers in Bioengineering and Biotechnology. 2024;12. doi:10.3389/fbioe.2024.1320337
BibTeX
@article{Jeon2024,
author = {Jeon, HyeongMin and Chung, Eun-Hye and Bak, Se-Young and Kim, Heegoo and Shin, Seyoung and Baek, Hongseok and Kim, MinYoung},
title = {Comparison of biomechanical parameters in lower limb joints of stroke patients according to conventional evaluation scores during level walking},
journal = {Frontiers in Bioengineering and Biotechnology},
year = {2024},
volume = {12},
doi = {10.3389/fbioe.2024.1320337}
}
EUVIMED