EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Sparse EEG neurodynamics of hypoglycemia in type 1 diabetes with personal euglycemic baseline adaptation

Farhad Hassan, Zubair Akbar, Ubaidullah Alias Kashif, Saheed Salahudeen Abdullahi, Jingzhen Li, Zihao Wang, Zedong Nie

Frontiers in Bioinformatics · 11.11.2026 · 6

DOI: 10.3389/fbinf.2026.2008238 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Bioinformatics, online erschienen am 11.11.2026. Verfasst von Farhad Hassan und 6 weiteren Autor:innen. Die Arbeit nennt 70 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Introduction

Hypoglycemia alters cerebral electrophysiological activity, providing a physiological basis for EEG-based detection. However, translation toward subject-independent monitoring remains constrained by uncertain minimum input requirements, insufficiently characterized stability of sparse representations and their physiological associations, and inter-participant baseline variability.

Methods

This study benchmarked 24 models spanning engineered-feature machine learning, feature-domain deep learning, and raw-waveform deep learning under leave-one-subject-out validation. Channel–Feature Sparsification was applied using a predefined performance-preservation criterion. Sparse representations were evaluated for selection stability, cross-paradigm concordance, and physiological association. Personal Euglycemic Baseline Adaptation (PEBA) was subsequently applied using a short personal euglycemic reference without participant-specific model retraining.

Results

LDA achieved the highest observed balanced accuracy within the engineered-feature paradigm, whereas Sinc-SSNET performed best in both deep-learning paradigms. Sparsification retained the F7 log-theta descriptor for LDA, the F7 channel row for feature-domain Sinc-SSNET, and two channels for raw-waveform Sinc-SSNET. F7 was retained across all three paradigms, and its log-theta descriptor increased during hypoglycemia in 30 of 34 participants (88.2%). PEBA improved balanced accuracy from 0.71 to 0.77 for LDA, from 0.68 to 0.83 for feature-domain Sinc-SSNET, and from 0.71 to 0.78 for raw-waveform Sinc-SSNET. Compared with the corresponding full-input models, reduced configurations decreased parameter counts by 88.51%–99.88%, parameter storage requirements by 87.20%–99.88%, and multiply–accumulate operations by 94.72%–99.91%.

Discussion

These findings demonstrate the preservation of hypoglycemia-related EEG information under a predefined sparsification criterion, while personal euglycemic normalization improves cross-participant discrimination. Physiological consistency and reduced computational requirements support further evaluation of compact EEG-based hypoglycemia detection. Independent cohorts, continuous glycemic-transition recordings, and native sparse EEG acquisition are required before prospective application.

Zitieren

APA

Hassan, F., Akbar, Z., Kashif, U. A., Abdullahi, S. S., Li, J., Wang, Z., & Nie, Z. (2026). Sparse EEG neurodynamics of hypoglycemia in type 1 diabetes with personal euglycemic baseline adaptation. Frontiers in Bioinformatics, 6. https://doi.org/10.3389/fbinf.2026.2008238

Vancouver

Hassan F, Akbar Z, Kashif UA, Abdullahi SS, Li J, Wang Z, et al. Sparse EEG neurodynamics of hypoglycemia in type 1 diabetes with personal euglycemic baseline adaptation. Frontiers in Bioinformatics. 2026;6. doi:10.3389/fbinf.2026.2008238

BibTeX
@article{Hassan2026,
  author = {Hassan, Farhad and Akbar, Zubair and Kashif, Ubaidullah Alias and Abdullahi, Saheed Salahudeen and Li, Jingzhen and Wang, Zihao and Nie, Zedong},
  title = {Sparse EEG neurodynamics of hypoglycemia in type 1 diabetes with personal euglycemic baseline adaptation},
  journal = {Frontiers in Bioinformatics},
  year = {2026},
  volume = {6},
  doi = {10.3389/fbinf.2026.2008238}
}
Kostenlos starten →