EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Cardiac vagal decoupling: a conceptual basis for reflex-independent hemodynamic management under general anesthesia

Shotaro Nagahama

Frontiers in Anesthesiology · 27.02.2026 · 5

DOI: 10.3389/fanes.2026.1756498 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Anesthesiology, online erschienen am 27.02.2026. Verfasst von Shotaro Nagahama. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 31 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Intraoperative hypotension is consistently associated with postoperative organ injury, and recent consensus statements emphasize maintaining mean arterial pressure above pragmatic “harm thresholds” in at-risk patients. Under balanced anesthesia, hypotension often arises in bradycardia-predominant contexts in which reflex pressure–heart rate coupling remains variably expressed. In such settings, reflex sinus slowing can complicate vasoactive titration and contribute to sequence-dependent, non-linear pressure–heart rate trajectories, particularly when vasopressors are followed by antimuscarinics. Here we present cardiac vagal decoupling as a conceptual framework for interpreting—and, when clinically appropriate, discussing—hemodynamic baselines in which subsequent pressor titration is less dominated by reflex sinus slowing, without implying abolition of reflex control or recommending a fixed drug sequence. Using atropine as a reference antimuscarinic, we outline why sinus-rate responses can appear abrupt by considering effector-level threshold-like behavior, sinoatrial node excitability near firing threshold, and non-monotonic muscarinic pharmacodynamics at low dose ranges. We then describe two broad, non-exclusive configurations in which atropine may produce little observable chronotropic change: globally reduced autonomic responsiveness vs. context-limited incremental expression within the muscarinic receptor–effector pathway. Finally, we propose a four-pattern heuristic combining atropine “responsiveness” with bedside evidence of reflex pressure–heart rate coupling to organize interpretation when one signal is missing or weakly expressed, while explicitly recognizing surrogate limitations and motivating empirical evaluation.

Zitieren

APA

Nagahama, S. (2026). Cardiac vagal decoupling: a conceptual basis for reflex-independent hemodynamic management under general anesthesia. Frontiers in Anesthesiology, 5. https://doi.org/10.3389/fanes.2026.1756498

Vancouver

Nagahama S. Cardiac vagal decoupling: a conceptual basis for reflex-independent hemodynamic management under general anesthesia. Frontiers in Anesthesiology. 2026;5. doi:10.3389/fanes.2026.1756498

BibTeX
@article{Nagahama2026,
  author = {Nagahama, Shotaro},
  title = {Cardiac vagal decoupling: a conceptual basis for reflex-independent hemodynamic management under general anesthesia},
  journal = {Frontiers in Anesthesiology},
  year = {2026},
  volume = {5},
  doi = {10.3389/fanes.2026.1756498}
}