EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Altered blood gas tensions of oxygen and carbon dioxide confound coronary reactivity to apnea

Kady Fischer, Dominik P. Guensch, Nancy Shie, Gobinath Nadeshalingham, Julie Lebel, Matthias G. Friedrich

Frontiers in Anesthesiology · 2022

DOI: 10.3389/fanes.2022.997836 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Frontiers in Anesthesiology, 2022. Verfasst von Kady Fischer und 5 weiteren Autor:innen. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 57 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Fondation Institut de Cardiologie de Montréal, Fonds de recherche du Québec.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Arterial blood gases change frequently during anesthesia and intensive care. Apnea can occur during diagnostic exams and airway and surgical interventions. While the impact of blood gas levels on coronary blood flow is established, their confounding effect on coronary vasoreactivity in response to an apneic stimulus, especially in coronary artery disease, is not known.

Methods

Six anesthetized control swine and eleven swine with coronary artery stenosis were examined. Nine different blood gas levels from a combination of arterial partial pressure of oxygen (70, 100, and 300 mmHg) and carbon dioxide (30, 40, and 50 mmHg) were targeted. Apnea was induced by halting controlled positive pressure ventilation for 3–30s, while the left descending coronary artery flow was measured and reported relative to apnea duration, and at the adjusted mean (12s).

Results

At normoxemic-normocapnic blood gas levels, apnea increased coronary blood flow in proportion to the duration of apnea in the control (r = 0.533, p < 0.001) and stenosed groups (r = 0.566, p < 0.001). This culminated in a 42% (95% CI: 27–58) increase in controls ( p < 0.001) and, to a lesser extent, 27% (15–40) in the presence of coronary artery stenosis ( p < 0.001). Vasoreactivity was augmented by mild-hypoxemic levels [81% (65–97), and 66% (53–79) increase in flow respectively, p < 0.001 vs. normoxemia], but markedly reduced during hyperoxia (7.5% (−8.2–23) and 0.3% (−12–13), respectively, p < 0.001 vs. normoxemia).

Conclusion

Alterations of blood oxygen and carbon dioxide affect coronary vascular reactivity induced by apnea in swine, which was attenuated further in the presence of coronary stenosis. Especially hyperoxia significantly reduces coronary blood flow and blunts coronary vascular reactivity.

Förderung

  • Fondation Institut de Cardiologie de Montréal
  • Fonds de recherche du Québec

Zitieren

APA

Fischer, K., Guensch, D. P., Shie, N., Nadeshalingham, G., Lebel, J., & Friedrich, M. G. (2022). Altered blood gas tensions of oxygen and carbon dioxide confound coronary reactivity to apnea. Frontiers in Anesthesiology. https://doi.org/10.3389/fanes.2022.997836

Vancouver

Fischer K, Guensch DP, Shie N, Nadeshalingham G, Lebel J, Friedrich MG. Altered blood gas tensions of oxygen and carbon dioxide confound coronary reactivity to apnea. Frontiers in Anesthesiology. 2022. doi:10.3389/fanes.2022.997836

BibTeX
@article{Fischer2022,
  author = {Fischer, Kady and Guensch, Dominik P. and Shie, Nancy and Nadeshalingham, Gobinath and Lebel, Julie and Friedrich, Matthias G.},
  title = {Altered blood gas tensions of oxygen and carbon dioxide confound coronary reactivity to apnea},
  journal = {Frontiers in Anesthesiology},
  year = {2022},
  doi = {10.3389/fanes.2022.997836}
}
Kostenlos starten →