EUVIMEDEUVIMED entdecken
LeserbriefOpen Access · CC BY 4.0

Longitudinal agreement of repeated critical haemoglobin measurements as evidence of sustained analytical quality

Vanda Simões, Cacilda Magalhães, Yuliana O Eremina

British Journal of Biomedical Science · 03.08.2026 · 83

DOI: 10.3389/bjbs.2026.16480 ↗

Kurz gefasst

Leserbrief in der Zeitschrift British Journal of Biomedical Science, online erschienen am 03.08.2026. Verfasst von Vanda Simões und 2 weiteren Autor:innen. Beteiligte Einrichtung: Clinical Pathology Department, Local Health Unit of Matosinhos, Matosinhos, Portugal. Die Arbeit nennt 10 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Dear Editors, Haemoglobin (Hb) values below 70 g/L are widely recognised as critical results and have traditionally prompted repeat analysis prior to reporting. This practice emerged as a quality assurance safeguard intended to detect potential analytical random or systematic errors before result validation, a practice whose clinical utility is increasingly being questioned [1,2], but still exists in many laboratories.In contemporary laboratory practice, however, highly automated haematology platforms operate with real-time flagging systems and advanced error detection algorithms. Furthermore, raw analytical data archived in analyser backups include repeated full/complete blood count (FBC/CBC) measurements performed for technical or clinical reasons, such as reflex testing, flag resolution, or platelet confirmation using alternative methods. These naturally occurring duplicate measurements generate a real-world dataset that can be analysed to monitor analytical performance and quantify imprecision under routine operating conditions [3].We conducted a retrospective longitudinal evaluation at a secondary public hospital, at the laboratory that serves a heterogeneous patient population, receiving samples from diverse clinical settings, including the emergency department, inpatient wards, day hospital services, and primary care centres. Raw analytical blocks of data were extracted from the back-up databases of three interconnected Sysmex XN-9100 modules between 2021 and 2025. Data management, exploratory data analysis and automated sample pairing were performed using R (version 4.4.3).A total of 499,965 haemograms were reviewed and, among these, 3,154 haemograms with Hb

Schlagwörter

Stichwörter der Autor:innen

critical haemoglobininternal quality controllongitudinal controlraw analytical datarepeated measurements

Autor:innen und Institutionen

  • Clinical Pathology Department, Local Health Unit of Matosinhos, Matosinhos, Portugal.
  • MEDCIDS, Faculty of Medicine, University of Porto, Porto, Portugal.
  • INESC TEC, Porto, Portugal.
  • EPIUnit - Public Health Institute, University of Porto, Porto, Portugal.
  • Laboratory for Integrative and Translational Investigation in Population Health (ITR), Porto, Portugal.

Zitieren

APA

Simões, V., Magalhães, C., & Eremina, Y. O. (2026). Longitudinal agreement of repeated critical haemoglobin measurements as evidence of sustained analytical quality. British Journal of Biomedical Science, 83. https://doi.org/10.3389/bjbs.2026.16480

Vancouver

Simões V, Magalhães C, Eremina YO. Longitudinal agreement of repeated critical haemoglobin measurements as evidence of sustained analytical quality. British Journal of Biomedical Science. 2026;83. doi:10.3389/bjbs.2026.16480

BibTeX
@article{Simes2026,
  author = {Simões, Vanda and Magalhães, Cacilda and Eremina, Yuliana O},
  title = {Longitudinal agreement of repeated critical haemoglobin measurements as evidence of sustained analytical quality},
  journal = {British Journal of Biomedical Science},
  year = {2026},
  volume = {83},
  doi = {10.3389/bjbs.2026.16480}
}
Kostenlos starten →