Introduction

Patient’s standard of care is utmost important during any dental procedure. Mishaps such as the accidental ingestion of Hex drivers or any implant components may occur during implant treatment. Although such accidents are rare, they can be potentially harmful to patients. The use of a rubber dam is not always possible in Dental Implantology; thus, the attachment of floss to Hex Drivers is commonly done during the usage of the driver. However, there are some challenges associated with using Flossed Hex Drivers (FHD). To overcome these difficulties, a system called i-Grip was introduced. To evaluate the perception and compare the ease, convenience and safety of i-Grip versus FHDs as perceived by Implantologists during screwing of any implant component in the internal connection of the implant. Material and Methods A post-test quasi-experimental study was conducted in the Department of Prosthodontics, crown and Bridge, Dr. G. D. Pol Foundation’s YMT Dental College and Hospital, Kharghar, Navi Mumbai, Maharashtra, India, among 40 Clinicians over a period of three months. The Implant Dentist were asked to use the i-Grip for four weeks, after which they completed validated questionnaires. Statistical Package for the Social Sciences (SPSS) software version 23.0 was used for data analysis. The answers to the questions were statistically analysed using the Z-test of proportion.

Results

The mean age of males were 45±0.743 years and females were 40.37±0.543 years. A total of 27 (67.5%) participants found placing the Hex Driver in the i-Grip to be very easy. 22 (55%) found the i-Grip to be very convenient to use. 31 (77.5%) Implantologists found the i-Grip to be extremely safe, 6 (15%) considered it to be moderately safe and none found it to be extremely unsafe. There was a statistically significant difference between the ease, comfort and safety of i-Grip compared to FHD (p

Zitieren

APA

Naware, A. (2026). Perception of Clinicians on Use of i-Grip with Hex Driver v/s Flossed Hex Driver during Routine Implant Procedures in Patients Indicated for Implant supported Prostheses: A Quasi-experimental Study. Journal of Indian Dental Association. https://doi.org/10.33882/jida.15.ida-11

Vancouver

Naware A. Perception of Clinicians on Use of i-Grip with Hex Driver v/s Flossed Hex Driver during Routine Implant Procedures in Patients Indicated for Implant supported Prostheses: A Quasi-experimental Study. Journal of Indian Dental Association. 2026. doi:10.33882/jida.15.ida-11

BibTeX
@article{Naware2026,
  author = {Naware, Anuj},
  title = {Perception of Clinicians on Use of i-Grip with Hex Driver v/s Flossed Hex Driver during Routine Implant Procedures in Patients Indicated for Implant supported Prostheses: A Quasi-experimental Study},
  journal = {Journal of Indian Dental Association},
  year = {2026},
  doi = {10.33882/jida.15.ida-11}
}
Kostenlos starten →