EUVIMEDEUVIMED entdecken
Crossref

ICA-Based Noise Reduction of Magnetocardiogram Signals Using a Hybrid BiLSTM-Residual CNN Network

N. Ahmed, M. Iwai, K. Kobayashi

Journal of the Magnetics Society of Japan · 2026

DOI: 10.3379/msjmag.2701r002 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Magnetics Society of Japan, 2026. Verfasst von N. Ahmed und 2 weiteren Autor:innen. Die Arbeit nennt 20 Literaturangaben.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Cardiac disorders such as ischemia and arrhythmia cause many people to suffer worldwide. Traditional electrocardiography (ECG) techniques have difficultly detecting these diseases effectively, which makes it even more difficult to identify heart problems. Doctors face challenges in diagnosing conditions properly. On the other hand, magnetocardiography (MCG) is a non-invasive diagnostic modality that records the magnetic fields generated by cardiac electrical activity, providing high-resolution, temporal and spatial information. It can quickly identify severe heart diseases and also assist in clinical diagnosis for understanding heart problems more promptly. Unshielded MCG recorded signals are typically weak compared with environmental magnetic noise and require a noise reduction technique, mainly at a low signal-to-noise ratio (SNR) where cardiac signals are extremely suppressed by noise. Independent component analysis (ICA) is widely used to decompose multichannel MCG recordings into independent components (ICs), which represent noise sources as well as cardiac-related feature signals. However, the accurate identification of ICs corresponding to true cardiac signals remains a critical challenge, particularly in low-SNR recordings, where conventional threshold-based or energy-based selection methods often fail, leading to misclassification and loss of signal reliability. To overcome these challenges, we propose a novel deep learning-based framework for automated binary classification of MCG components and noise components using ICA, leveraging a hybrid Bidirectional Long Short-Term Memory (BiLSTM) and residual Convolutional Neural Network (CNN) architecture, for automated IC classification in a noisy environment. This framework was trained using only 0-dB data and was evaluated with SNR data at 0, −10, and −20 dB. The proposed method allowed for the automatic selection of MCG components. The results demonstrate the effectiveness of the method in reducing noise in MCG signals across various SNR levels.

Zitieren

APA

Ahmed, N., Iwai, M., & Kobayashi, K. (2026). ICA-Based Noise Reduction of Magnetocardiogram Signals Using a Hybrid BiLSTM-Residual CNN Network. Journal of the Magnetics Society of Japan. https://doi.org/10.3379/msjmag.2701r002

Vancouver

Ahmed N, Iwai M, Kobayashi K. ICA-Based Noise Reduction of Magnetocardiogram Signals Using a Hybrid BiLSTM-Residual CNN Network. Journal of the Magnetics Society of Japan. 2026. doi:10.3379/msjmag.2701r002

BibTeX
@article{Ahmed2026,
  author = {Ahmed, N. and Iwai, M. and Kobayashi, K.},
  title = {ICA-Based Noise Reduction of Magnetocardiogram Signals Using a Hybrid BiLSTM-Residual CNN Network},
  journal = {Journal of the Magnetics Society of Japan},
  year = {2026},
  doi = {10.3379/msjmag.2701r002}
}
Kostenlos starten →