EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Fabrication and Characterization of Epoxy Resin Co-doped with 2,5-Diphenyloxazole and Cerium Fluoride Nanoparticles for Radiation Detection

Akapong Phunpueok, Jaruwan Seangrit, Sarawut Jaiyen, Krittiya Sreebunpeng, Wuttichai Chaiphaksa, Kewalee Nilgumhang, Voranuch Thongpool

Karbala International Journal of Modern Science · 23.09.2025 · 11 (4)

DOI: 10.33640/2405-609x.3429 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Karbala International Journal of Modern Science, online erschienen am 23.09.2025. Verfasst von Akapong Phunpueok und 6 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

This paper presents the fabrication and characterization of a plastic scintillator prepared from epoxy resin doped with 2,5-diphenyloxazole (PPO) and cerium fluoride nanoparticles (CeF3 NPs) for radiation detection. The CeF3 NPs were prepared by a chemical process and examined by X-ray diffraction (XRD) and scanning electron microscopy (SEM); it was found that the prepared particles were true CeF3 NPs with an average particle size of approximately 17 nm. The CeF3 NPs were co-doped with PPO into epoxy resin and formed into a plastic scintillator of 3 cm in diameter and 2 cm in length. Analysis of the scintillator's luminescence properties using a fluorescence spectrometer revealed that excitation at 300 nm resulted in maximum emission at 366 nm. Scintillation response testing, conducted by coupling the plastic scintillator to a photomultiplier tube, demonstrated successful radiation detection capabilities. The optimal sample preparation conditions were determined to be 0.4% by weight of PPO doping and 0.2% by weight of CeF3 NPs co-doping, which yielded the best gamma-ray detection performance. Energy response testing using radiation sources Na-22, Cs-137, Mn-54, and Co-60 showed that the relationship between incident gamma-ray energy and the signal measured by the multichannel analyzer exhibited 99.83% linearity. For measuring gamma rays at 662 keV, the fabricated plastic scintillator showed a light yield of 1,810 photons/MeV, corresponding to 39% of that of a commercial plastic scintillator (4,640 photons/MeV). The fabricated plastic scintillators were also responsive to X-rays and alpha particles; namely, when excited with X-rays, they exhibited a scintillation efficiency equal to 15% of that of the reference BGO crystal, and when excited with 5.5 MeV alpha particles from Pu-238, they showed an energy resolution of 48.27%.

Zitieren

APA

Phunpueok, A., Seangrit, J., Jaiyen, S., Sreebunpeng, K., Chaiphaksa, W., Nilgumhang, K., & Thongpool, V. (2025). Fabrication and Characterization of Epoxy Resin Co-doped with 2,5-Diphenyloxazole and Cerium Fluoride Nanoparticles for Radiation Detection. Karbala International Journal of Modern Science, 11(4). https://doi.org/10.33640/2405-609x.3429

Vancouver

Phunpueok A, Seangrit J, Jaiyen S, Sreebunpeng K, Chaiphaksa W, Nilgumhang K, et al. Fabrication and Characterization of Epoxy Resin Co-doped with 2,5-Diphenyloxazole and Cerium Fluoride Nanoparticles for Radiation Detection. Karbala International Journal of Modern Science. 2025;11(4). doi:10.33640/2405-609x.3429

BibTeX
@article{Phunpueok2025,
  author = {Phunpueok, Akapong and Seangrit, Jaruwan and Jaiyen, Sarawut and Sreebunpeng, Krittiya and Chaiphaksa, Wuttichai and Nilgumhang, Kewalee and Thongpool, Voranuch},
  title = {Fabrication and Characterization of Epoxy Resin Co-doped with 2,5-Diphenyloxazole and Cerium Fluoride Nanoparticles for Radiation Detection},
  journal = {Karbala International Journal of Modern Science},
  year = {2025},
  volume = {11},
  number = {4},
  doi = {10.33640/2405-609x.3429}
}
Kostenlos starten →