EUVIMEDEUVIMED entdecken
Crossref

Modeling Intercapillary Distance as a Regulator of Tissue Denitrogenation Rate

Todd Dart, Jeffrey Mock, Jeremy Beer

Aerospace Medicine and Human Performance · 2026-03 · 97 (3) · 137-144

DOI: 10.3357/amhp.6810.2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aerospace Medicine and Human Performance, 2026-03. Verfasst von Todd Dart und 2 weiteren Autor:innen. Hauptthemen laut MEDLINE: Nitrogen, Decompression Sickness, Capillaries, Oxygen. Die Arbeit nennt 64 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Removing nitrogen gas from body tissue by breathing 100% oxygen (denitrogenation) before exposure to a low-pressure environment reduces risk of decompression sickness (DCS) caused by nitrogen bubble formation. This is a priority in activities that include DCS risk such as unpressurized flight or astronaut extravehicular activity. Tissue denitrogenation is determined by perfusion, so modeling intercapillary distance (ICD) as a perfusion characteristic could be exploited to predict denitrogenation efficiency. METHODS: Five inert gas exchange models were developed that combine a cylindrical conceptualization of tissue surrounding a single capillary (Krogh model) in which denitrogenation can occur, with estimates of ICD from 10–50 µm used to represent capillary density. Rate of nitrogen washout (dPN 2 · dt −1 ) was estimated using ICD and initial tissue nitrogen pressure as predictor variables. Regressions were performed to compare model output to fractional washout volumes obtained using Behnke’s whole-body washout functions as a benchmark. RESULTS: Mean denitrogenation fractions generated by these mixed-venous models correlated strongly with fractional Behnke washout curves (Pearson’s r = 1). Emergent tissue nitrogen washout half-time rates ranged from 5.5–90 min. Differences in lean and adipose tissue ICD and nitrogen solubility impact tissue nitrogen concentration but not pressure. DISCUSSION: The use of a “leaky nitrogen reservoir” multicylinder ICD perfusion model offers a theoretical framework on which to base denitrogenation rates within and across tissue types. This modeling approach may permit the development of improved perfusion-enhancing denitrogenation strategies and DCS risk models. Dart T, Mock J, Beer J. Modeling intercapillary distance as a regulator of tissue denitrogenation rate . Aerosp Med Hum Perform. 2026; 97(3):137–144.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

NitrogenDecompression SicknessCapillariesOxygenModels, BiologicalHumans

Stichwörter der Autor:innen

decompression sicknesshalf-timenitrogenperfusionprebreathe

Substanzen

NitrogenOxygen

Zitieren

APA

Dart, T., Mock, J., & Beer, J. (2026). Modeling Intercapillary Distance as a Regulator of Tissue Denitrogenation Rate. Aerospace Medicine and Human Performance, 97(3), 137-144. https://doi.org/10.3357/amhp.6810.2026

Vancouver

Dart T, Mock J, Beer J. Modeling Intercapillary Distance as a Regulator of Tissue Denitrogenation Rate. Aerospace Medicine and Human Performance. 2026;97(3):137-144. doi:10.3357/amhp.6810.2026

BibTeX
@article{Dart2026,
  author = {Dart, Todd and Mock, Jeffrey and Beer, Jeremy},
  title = {Modeling Intercapillary Distance as a Regulator of Tissue Denitrogenation Rate},
  journal = {Aerospace Medicine and Human Performance},
  year = {2026},
  volume = {97},
  number = {3},
  pages = {137--144},
  doi = {10.3357/amhp.6810.2026}
}
Kostenlos starten →