EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC-ND 4.0

Using Near Infrared Light to Detect Hypoxia in Retinal Images

Amerens Bekkers, Vincent Zoutenbier, Peter Bussink, Eric Groen, Hugo Kuijf, Arjen Amelink

Aerospace Medicine and Human Performance · 2026-02 · 97 (2) · 111-115

DOI: 10.3357/amhp.6789.2026 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aerospace Medicine and Human Performance, 2026-02. Verfasst von Amerens Bekkers und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Hypoxia, Retinal Vessels, Infrared Rays, Retina. Die Arbeit nennt 22 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC-ND 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: Acute hypoxia poses a serious risk in military aviation because it can lead to impaired performance of safety-critical tasks. Early detection of hypoxia is therefore critical. Oxygen saturation (S p o 2 ) of the retinal blood vessels may serve as a surrogate biomarker for brain hypoxia. This study investigates the feasibility of detecting hypoxia through retinal imaging in the near-infrared (NIR) spectrum, which does not interfere with the pilot’s vision. METHODS: There were 12 subjects who participated in a hypobaric flight simulation to lower systemic S p o 2 . Retinal images were captured using a dual-wavelength NIR fundus camera, while S p o 2 was measured via fingertip pulse oximetry. The optical density (OD) of retinal blood vessels was extracted from the images at both wavelengths. It was hypothesized that the ratio of vessel OD between the two wavelengths increases with rising S p o 2 . RESULTS: Measured S p o 2 was compared with the calculated OD ratio. No correlation was found between the OD ratio and S p o 2 . DISCUSSION: NIR retinal imaging appears to be unsuitable for accurate hypoxia detection within an acceptable ±4% error margin using our imaging protocol. This is mainly due to the low contrast of blood vessels in the NIR wavelength region, along with limited imaging repeatability resulting from realignment and refocusing steps in the imaging protocol. These factors have a larger distorting effect on the images than the subtle OD ratio changes related to varying S p o 2 . Bekkers A, Zoutenbier V, Bussink P, Groen E, Kuijf H, Amelink A. Using near infrared light to detect hypoxia in retinal images . Aerosp Med Hum Perform. 2026; 97(2):111–115.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

HypoxiaRetinal VesselsInfrared RaysRetinaHumansOximetryOxygen SaturationAdultMaleAerospace MedicineMilitary PersonnelSpectroscopy, Near-InfraredFeasibility StudiesOxygen

Stichwörter der Autor:innen

brain hypoxia monitoringretinal oximetry

Substanzen

Oxygen

Zitieren

APA

Bekkers, A., Zoutenbier, V., Bussink, P., Groen, E., Kuijf, H., & Amelink, A. (2026). Using Near Infrared Light to Detect Hypoxia in Retinal Images. Aerospace Medicine and Human Performance, 97(2), 111-115. https://doi.org/10.3357/amhp.6789.2026

Vancouver

Bekkers A, Zoutenbier V, Bussink P, Groen E, Kuijf H, Amelink A. Using Near Infrared Light to Detect Hypoxia in Retinal Images. Aerospace Medicine and Human Performance. 2026;97(2):111-115. doi:10.3357/amhp.6789.2026

BibTeX
@article{Bekkers2026,
  author = {Bekkers, Amerens and Zoutenbier, Vincent and Bussink, Peter and Groen, Eric and Kuijf, Hugo and Amelink, Arjen},
  title = {Using Near Infrared Light to Detect Hypoxia in Retinal Images},
  journal = {Aerospace Medicine and Human Performance},
  year = {2026},
  volume = {97},
  number = {2},
  pages = {111--115},
  doi = {10.3357/amhp.6789.2026}
}
Kostenlos starten →