Cold Protection and Manual Performance Assessment of Aircrew Gloves
Aerospace Medicine and Human Performance · 2026-03 · 97 (3) · 160-168
DOI: 10.3357/amhp.6701.2026 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aerospace Medicine and Human Performance, 2026-03. Verfasst von Andrew S Weller und 1 weiteren Autor:innen. Hauptthemen laut MEDLINE: Gloves, Protective, Cold Temperature, Aircraft. Die Arbeit nennt 58 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: Military aircrew of rotary-wing aircraft often report cold and dysfunctional hands during cold-weather flying. Therefore, the cold protection and manual performance of in-service gloves was quantified in a laboratory study to support cold-weather advice to aircrew and glove procurement activities. METHODS: There were 8 civilian men who undertook a 60-min thermal test simulating the metabolic cost of rear crew physical tasks and wearing representative clothing on 15 occasions, where 3 main glove types (Cape leather, C; Cape + silk liner, C + S; Gunner, G) and 5 air temperatures (T A ; +20, +10, 0, −10, −20°C) were assessed. Physiological (including mean finger skin temperature, T FSK ), subjective thermal, and manual performance (including bare-hand and gloved finger/hand dexterity) measures were obtained. RESULTS: At a T A of 0°C, mean T SKF was 15.2 (C), 17.9 (C + S), and 22.4°C (G). Finger cold discomfort occurred at a T A of 0°C in C, and at −10°C in C + S and G. Gloved finger/hand dexterity was impaired relative to bare hands by 46/4 (C), 56/14 (C + S), and 73/44% (G). There was no relationship between T SKF and dexterity performance. DISCUSSION: The performance of aircrew gloves has been baselined for male aircrew. Cape leather gloves are limited to a T A of +10°C. Adding silk liners and wearing the Gunner glove extended exposure down to a T A of 0°C but imposed considerable impairment on dexterity performance. Solutions are required to enhance cold protection at a lower cost to manual performance, which must demonstrate applicability to both male and female aircrew. Weller AS, Boyd JWR. Cold protection and manual performance assessment of aircrew gloves . Aerosp Med Hum Perform. 2026; 97(3):160–168.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Zitieren
APA
Weller, A. S., & Boyd, J. W. R. (2026). Cold Protection and Manual Performance Assessment of Aircrew Gloves. Aerospace Medicine and Human Performance, 97(3), 160-168. https://doi.org/10.3357/amhp.6701.2026
Vancouver
Weller AS, Boyd JWR. Cold Protection and Manual Performance Assessment of Aircrew Gloves. Aerospace Medicine and Human Performance. 2026;97(3):160-168. doi:10.3357/amhp.6701.2026
BibTeX
@article{Weller2026,
author = {Weller, Andrew S and Boyd, Jonathan W R},
title = {Cold Protection and Manual Performance Assessment of Aircrew Gloves},
journal = {Aerospace Medicine and Human Performance},
year = {2026},
volume = {97},
number = {3},
pages = {160--168},
doi = {10.3357/amhp.6701.2026}
}
EUVIMED