Seasickness Simulator to Assess Anti-Motion Sickness Devices
Aerospace Medicine and Human Performance · 2025
DOI: 10.3357/amhp.6403.2025 ↗Kurz gefasst
Fachartikel in der Zeitschrift Aerospace Medicine and Human Performance, 2025. Verfasst von Camille de Thierry de Faletans und 4 weiteren Autor:innen. Hauptthemen laut MEDLINE: Motion Sickness. Die Arbeit nennt 32 Literaturangaben.
Abstract (Originalsprache)
INTRODUCTION: There are various motion sickness (MS) simulators in the laboratory, but the conditions under which they induce MS symptoms are different from real-life conditions. This study aimed to design a seasickness simulator, close to ecological conditions, easy to set up, at a modest cost, and capable of rapidly inducing MS symptoms, to evaluate the effect of anti-motion sickness devices. The hypothesis was that this simulator would induce MS, reflecting the susceptibility of subjects in real-life conditions, meaning the more susceptible individuals were to MS in real conditions, the more severe and rapid their symptoms would be in the simulator. METHODS: A total of 65 subjects with varying degrees of MS susceptibility (MS Susceptibility Questionnaire Short form) were exposed to a seasickness simulator for a maximum of 10 min. Measurements of subjective symptoms (Visual Analog Scale and time to onset of first symptoms) and physiological variables (heart rate and temperature) were taken. RESULTS: Subjects covered the full range of MS susceptibility (from 0–100%). The average time in the simulator before the first symptoms of MS was 7.41 min ± 2.56 min. The time to onset of the first symptoms, the intensity of the symptoms, and heart rate were significantly correlated with the degree of susceptibility of subjects in real-life conditions. DISCUSSION: The simulator induced varying intensity of MS depending on the subjects’ susceptibility. It thus replicates real-life conditions and can serve as a useful tool for facilitating the research of devices, techniques, and medications to combat MS. de Thierry de Faletans C, Misericordia M, Vallier J-M, Duché P, Watelain E. Seasickness simulator to assess anti-motion sickness devices . Aerosp Med Hum Perform. 2025; 96(3):212–218.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Zitieren
APA
de Thierry de Faletans, C., Misericordia, M., Vallier, J. M., Duché, P., & Watelain, E. (2025). Seasickness Simulator to Assess Anti-Motion Sickness Devices. Aerospace Medicine and Human Performance. https://doi.org/10.3357/amhp.6403.2025
Vancouver
de Thierry de Faletans C, Misericordia M, Vallier JM, Duché P, Watelain E. Seasickness Simulator to Assess Anti-Motion Sickness Devices. Aerospace Medicine and Human Performance. 2025. doi:10.3357/amhp.6403.2025
BibTeX
@article{deThierrydeFaletans2025,
author = {de Thierry de Faletans, Camille and Misericordia, Maxime and Vallier, Jean-Marc and Duché, Pascale and Watelain, Eric},
title = {Seasickness Simulator to Assess Anti-Motion Sickness Devices},
journal = {Aerospace Medicine and Human Performance},
year = {2025},
doi = {10.3357/amhp.6403.2025}
}
EUVIMED