X-Ray Imaging in the Simulated Microgravity Environment of Parabolic Flight

David Lerner, Michael Pohlen, Adam Wang, Jeanne Walter, Michael Cairnie, Sheyna Gifford

Aerospace Medicine and Human Performance · 01.10.2023 · 94 (10) · 786-791

DOI: 10.3357/amhp.6286.2023 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Aerospace Medicine and Human Performance, erschienen am 01.10.2023. Verfasst von David Lerner und 5 weiteren Autor:innen. Hauptthemen laut MEDLINE: Weightlessness, Space Flight. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 18 Literaturangaben.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

INTRODUCTION: The advancement of human spaceflight has made urgent the need to develop medical imaging technology to ensure a high level of in-flight care. To date, only ultrasound has been used in spaceflight. Radiography has multiple advantages over ultrasound, including lower operator dependence, more rapid acquisition, typically higher spatial resolution, and characterization of tissue with acoustic impedance precluding ultrasound. This proof-of-concept work demonstrates for the first time the feasibility of performing human radiographs in microgravity. METHODS: Radiographs of a phantom and human subject’s hand, knee, chest, cervical spine, and pelvis were obtained aboard a parabolic flight in microgravity and simulated lunar gravity with various subject and operator positions. Control radiographs were acquired with the same system on the ground. These radiographs were performed with a Food and Drug Administration-approved ultra-portable, wireless, battery-powered, digital x-ray system. RESULTS: The radiographs of the phantom acquired in reduced gravity were qualitatively and quantitatively compared to the ground controls and found to exhibit similar diagnostic adequacy. There was no statistically significant difference in contrast resolution or spatial resolution with a spatial resolution across all imaging environments up to the Nyquist frequency of 3.6 line-pairs/mm and an average contrast-to-noise ratio of 2.44. DISCUSSION: As mass, power, and volume limitations lessen over the coming decades and the miniaturization of imaging equipment continues, in-flight implementation of nonsonographic modalities will become practical. Given the demonstrated ease of use and satisfactory image quality, portable radiography is ready to be the new frontier of space medical imaging. Lerner D, Pohlen M, Wang A, Walter J, Cairnie M, Gifford S. X-ray imaging in the simulated microgravity environment of parabolic flight . Aerosp Med Hum Perform. 2023; 94(10):786–791.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

WeightlessnessSpace FlightUnited StatesHumansX-RaysRadiographyHypogravity

Zitieren

APA

Lerner, D., Pohlen, M., Wang, A., Walter, J., Cairnie, M., & Gifford, S. (2023). X-Ray Imaging in the Simulated Microgravity Environment of Parabolic Flight. Aerospace Medicine and Human Performance, 94(10), 786-791. https://doi.org/10.3357/amhp.6286.2023

Vancouver

Lerner D, Pohlen M, Wang A, Walter J, Cairnie M, Gifford S. X-Ray Imaging in the Simulated Microgravity Environment of Parabolic Flight. Aerospace Medicine and Human Performance. 2023;94(10):786-791. doi:10.3357/amhp.6286.2023

BibTeX
@article{Lerner2023,
  author = {Lerner, David and Pohlen, Michael and Wang, Adam and Walter, Jeanne and Cairnie, Michael and Gifford, Sheyna},
  title = {X-Ray Imaging in the Simulated Microgravity Environment of Parabolic Flight},
  journal = {Aerospace Medicine and Human Performance},
  year = {2023},
  volume = {94},
  number = {10},
  pages = {786--791},
  doi = {10.3357/amhp.6286.2023}
}
Kostenlos starten →