EUVIMEDEUVIMED entdecken
Crossref

Effects of Element Directivity in Linear-Array Photoacoustic Imaging

Bahador Makkiabadi

Archives in Biomedical Engineering & Biotechnology · 2018

DOI: 10.33552/abeb.2018.01.000504 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Archives in Biomedical Engineering & Biotechnology, 2018. Verfasst von Bahador Makkiabadi.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Photoacoustic imaging (PAI) is an emerging medical imaging modality with a steady growth in both pre-clinical and clinical applications. In linear-array PAI, beamformers play a significant role in the image reconstruction procedure. Generally, beamformers assume a pointlike model for the elements of the array, and the elements are assumed to be omnidirectional. In this study, we investigated the effects of receiver element directivity on the Photoacoustic (PA) image formation procedure where delay-andsum (DAS) and delay-multiply-and-sum (DMAS) algorithms have been used as beamformers. The proposed method is evaluated experimentally (wire phantom and ex vivo imaging). It has been shown that the contribution of the directivity of the transducer elements improves the PA image quality. The results show that using the directivity, the sidelobes of the formed image (wire phantom) by DAS are attenuated about 20 %, compared to when directivity is not used. Moreover, signal-to-noise ratio achieved by DAS and DMAS is improved by about 12.5 % and 11.3 %, respectively. Abbreviations : PAI: Photo Acoustic Imaging; PA: Photo Acoustic; DAS: Delay-And-Sum; DMAS: Delay-Multiply-And-Sum; MV: Minimum variance; DS-DMAS: Double stageDelay-Multiply-And-Sum; MCF: Modified Version of the Coherence Factor; US: Ultrasound This work is licensed under Creative Commons Attribution 4.0 License ABEB.MS.ID.000504. Archives in Biomedical Engineering & Biotechnology Volume 1-Issue 1 Citation: Moein M, Bahador M, Mohammad M. Effects of Element Directivity in Linear-Array Photoacoustic Imaging. Arch Biomed Eng & Biotechnol. 1(1): 2018. ABEB.MS.ID.000504. Page 2 of 7 the Coherence Factor (MCF) was introduced based on the DMAS, and it was shown that it provides a higher contrast compared to conventional CF [22,23]. In order to improve the resolution of DMAS, MV and its eigenspace version have been combined with the expansion of DMAS [24,25]. Directivity was investigated in the case that MV was used as the beamformer for linear-array Ultrasound (US) imaging. Also, it has been used for image improvement in circular PA tomography [14]. It has been shown that considering the element directivity decreases the error of the desired signal estimation and increases the spatial resolution of the formed image [26]. In this study, the effects of the element’s directivity are evaluated where DAS and DMAS beamformers are used as the reconstruction algorithms. The results show that the contribution of the elements directivity would improve the PA image quality. Materials and Methods Effects of directivity Generally, beamformers assume a point-like model for the elements of array. To put it more simply, the directivity of the element of array is not considered in image reconstruction procedure, and the elements are assumed to be omnidirectional. In [26], it has been shown that discarding directivity of the transducers affects the formed images. The detected signals from a target can be strengthened or weakened based on the position of the target. In other words, the directivity pattern of the transducer influences the detected signals, and also the formed images. To illustrate this, consider (Figure 1) where there are two targets located at (r1, θ1) and (r2, θ2). Assuming r1m = r2m, the PA signals generated by these targets will arrive to the element l2 simultaneously. The detected signal caused by the target located at (r1, θ1) would be dominant since the angle θ1m coincides with the direction of the maximum radiation of the element l2. On the other hand, the obtained signal caused by the target located at (r2, θ2) would be weakened since the angle θ2m makes the target far from the direction of the maximum radiation of the element l2. Consequently, an erroneous signal which presents information about the target located at (r2, θ2) is detected by the element l2. To address this problem, the observation angle needs to be considered in the PA image reconstruction algorithms. When PA signals are detected by a linear-array of US transducers, beamforming algorithms such as DAS can be used to reconstruct the PA image. DAS can be written as follows: 1 ( ) ( ) M DAS i i i y k x k = = − ∆ (1) Figure 1: The targets located at different coordinates are being seen by elements at different angles. where yDAS(k) is the output of the beamformer, k is the time index, M is the number of elements of array, and xi(k) and ∆i are the detected signals and the corresponding time delay for detector i, respectively. Implementing the DAS beamformer is simple which is why it is the most common beamforming algorithm in US and PAI. However, this algorithm provides a low off-axis signal rejection and noise suppression. Consequently, DAS results in reconstructed images having high levels of sidelobe and a low resolution. To address the limitations of DAS, DMAS was suggested in [17]. Similar to DAS, DMAS calculates corresponding samples for each element of the array based on the delays, but samples go through a correlation process before adding them up. The DMAS formula is as follows: 1 ( ) ( ) 1, 1 ( ) DMAS M M x k x k i j i i i i j y k − − ∆ − ∆ = = + = (2) To overcome the dimensionally squared problem of (2), following modifications are suggested in [17]:  ( ) [ ( )], ( ) ( ) ij i i i i j j x k sign x k x k x k = −∆ −∆ −∆ (3)  1 ( ) 1, 1 ( ) DMAS M M x k ij i j i y k − = = + = (4) Including the directivity in the beamforming algorithm results in the following equation: 1 ( ) ( ) ( ) M DAS Directivity i ik i i y k D x k θ + = = − ∆ (5) where θik is the angle between the element i and pixel k. The directivity factor can be expressed as sin( / sin( )) ( ) cos( ) / sin( ) ik ik ik ik d D d λ θ θ θ λ θ Π = Π (6)

Zitieren

APA

Makkiabadi, B. (2018). Effects of Element Directivity in Linear-Array Photoacoustic Imaging. Archives in Biomedical Engineering & Biotechnology. https://doi.org/10.33552/abeb.2018.01.000504

Vancouver

Makkiabadi B. Effects of Element Directivity in Linear-Array Photoacoustic Imaging. Archives in Biomedical Engineering & Biotechnology. 2018. doi:10.33552/abeb.2018.01.000504

BibTeX
@article{Makkiabadi2018,
  author = {Makkiabadi, Bahador},
  title = {Effects of Element Directivity in Linear-Array Photoacoustic Imaging},
  journal = {Archives in Biomedical Engineering & Biotechnology},
  year = {2018},
  doi = {10.33552/abeb.2018.01.000504}
}
Kostenlos starten →