Practical Barriers to Real-World Implementation of Artificial Intelligence-Driven CT-Derived Fractional Flow Reserve
Korean Journal of Radiology · 2026 · 27 (6) · 509
DOI: 10.3348/kjr.2025.1986 ↗Kurz gefasst
Editorial in der Zeitschrift Korean Journal of Radiology, 2026. Verfasst von Moon Young Kim und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Republic of Korea. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 24 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Noninvasive coronary CT angiography (CCTA) has been firmly established as a first-line imaging modality for evaluating suspected coronary artery disease (CAD) [1,2].Nevertheless, the well-known discordance between the severity of anatomical stenosis and functional ischemia remains a central challenge, particularly for intermediate lesions [3].CT-derived fractional flow reserve (CT-FFR) extends cardiac CT from morphology to physiology and has consistently demonstrated improved diagnostic accuracy compared with CCTA alone [4-6].Computational fluid dynamics-based off-site CT-FFR (e.g., HeartFlow) has been the most extensively validated, and artificial intelligence (AI)-based on-site CT-FFR aims to enhance workflow integration and scalability [7].AI-based CT-FFR is widely anticipated as a scalable and workflow-integrated solution that offers rapid on-site analysis without additional scanning [5,8].
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Radiology, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Republic of Korea.
- Department of Radiology, Seoul National University College of Medicine, Seoul, Republic of Korea.
- Department of Radiology, Samsung Medical Center, Seoul, Republic of Korea.
- Cardiovascular Imaging Center, Heart Vascular and Stroke Institute, Samsung Medical Center, Seoul, Republic of Korea. ychoe11@gmail.com.
ORCID-Profile: Moon Young Kim, Kwang Nam Jin, Yeon Hyeon Choe
Zitieren
APA
Kim, M. Y., Jin, K. N., & Choe, Y. H. (2026). Practical Barriers to Real-World Implementation of Artificial Intelligence-Driven CT-Derived Fractional Flow Reserve. Korean Journal of Radiology, 27(6), 509. https://doi.org/10.3348/kjr.2025.1986
Vancouver
Kim MY, Jin KN, Choe YH. Practical Barriers to Real-World Implementation of Artificial Intelligence-Driven CT-Derived Fractional Flow Reserve. Korean Journal of Radiology. 2026;27(6):509. doi:10.3348/kjr.2025.1986
BibTeX
@article{Kim2026,
author = {Kim, Moon Young and Jin, Kwang Nam and Choe, Yeon Hyeon},
title = {Practical Barriers to Real-World Implementation of Artificial Intelligence-Driven CT-Derived Fractional Flow Reserve},
journal = {Korean Journal of Radiology},
year = {2026},
volume = {27},
number = {6},
pages = {509},
doi = {10.3348/kjr.2025.1986}
}
EUVIMED