Safety and Effectiveness of Passeo-18 Lux Drug-Coated Balloon Catheter in Infrainguinal Endovascular Revascularization in the Korean Population: A Multicenter Post-Market Surveillance Study
Korean Journal of Radiology · 2024
DOI: 10.3348/kjr.2024.0099 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Korean Journal of Radiology, 2024. Verfasst von Tae Won Choi und 9 weiteren Autor:innen. Beteiligte Einrichtung: Department of Radiology, Ajou University Hospital, Ajou University School of Medicine, Suwon, Republic of Korea. Hauptthemen laut MEDLINE: Peripheral Arterial Disease, Product Surveillance, Postmarketing, Angioplasty, Balloon. Die Arbeit nennt 45 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Biotronik.
Abstract (Originalsprache)
OBJECTIVE: To evaluate the safety and clinical outcomes of the Passeo-18 Lux drug-coated balloon (DCB) in endovascular revascularization procedures under real-world conditions in a Korean population with atherosclerotic disease of the infrainguinal arteries, including below-the-knee (BTK) arteries. MATERIALS AND METHODS: Eight institutions in the Republic of Korea participated in this prospective, multicenter, single-arm, post-market surveillance study. Two hundred patients with Rutherford class 2-5 peripheral arterial disease and infrainguinal lesions suitable for endovascular treatment were competitively enrolled. Data were collected at baseline, the time of intervention, discharge, and 1-, 6-, 12-, and 24-month follow-up visits. The primary safety endpoint was freedom from major adverse events (MAE) within 6 months (except when limiting the time frame for procedure- or device-related mortality to within 30 days), and the primary effectiveness endpoint was freedom from clinically driven target lesion revascularization (CD-TLR) within 12 months after the procedure. RESULTS: A total of 197 patients with 332 target lesions were analyzed. Two-thirds of the patients had diabetes mellitus, and 41.6% had chronic limb-threatening ischemia. The median target lesion length was 100 mm (interquartile range: 56-133 mm). Of the target lesions, 35.2% were occlusions, and 14.8% were located in the BTK arteries. Rate of freedom from MAE was 97.9% at 6 months, and the rate of freedom from CD-TLR was 95.0% and 92.2% at 12 and 24 months, respectively. Subgroup analysis of 43 patients and 49 target lesions involving the BTK arteries showed rate of freedom from MAE of 92.8% at 6 months and rates of freedom from CD-TLR of 88.8% and 84.4% at 12 and 24 months, respectively. CONCLUSION: The results of the present study, including the BTK subgroup analysis, showed outcomes comparable to those of other DCB studies, confirming the safety and effectiveness of Passeo-18 Lux DCB in the Korean population.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Radiology, Ajou University Hospital, Ajou University School of Medicine, Suwon, Republic of Korea.
- Department of Radiology, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea.
- Department of Radiology, Inha University Hospital, Inha University School of Medicine, Incheon, Republic of Korea.
- Department of Radiology, Konkuk University Hospital, Konkuk University School of Medicine, Seoul, Republic of Korea.
- Department of Radiology, Asan Medical Center, University of Ulsan College of Medicine, Seoul, Republic of Korea.
- Department of Radiology, Chonnam National University Hospital, Chonnam National University Medical School, Gwangju, Republic of Korea.
ORCID-Profile: Tae Won Choi, Je Hwan Won, Hwan Jun Jae, Yong Sun Jeon, Sang Woo Park, Gi-Young Ko, Nam Yeol Yim, Jong Yun Won, Chang Won Kim, Jinoo Kim
Förderung
- Biotronik
Zitieren
APA
Choi, T. W., Won, J. H., Jae, H. J., Jeon, Y. S., Park, S. W., Ko, G. Y., Yim, N. Y., Won, J. Y., Kim, C. W., & Kim, J. (2024). Safety and Effectiveness of Passeo-18 Lux Drug-Coated Balloon Catheter in Infrainguinal Endovascular Revascularization in the Korean Population: A Multicenter Post-Market Surveillance Study. Korean Journal of Radiology. https://doi.org/10.3348/kjr.2024.0099
Vancouver
Choi TW, Won JH, Jae HJ, Jeon YS, Park SW, Ko GY, et al. Safety and Effectiveness of Passeo-18 Lux Drug-Coated Balloon Catheter in Infrainguinal Endovascular Revascularization in the Korean Population: A Multicenter Post-Market Surveillance Study. Korean Journal of Radiology. 2024. doi:10.3348/kjr.2024.0099
BibTeX
@article{Choi2024,
author = {Choi, Tae Won and Won, Je Hwan and Jae, Hwan Jun and Jeon, Yong Sun and Park, Sang Woo and Ko, Gi-Young and Yim, Nam Yeol and Won, Jong Yun and Kim, Chang Won and Kim, Jinoo},
title = {Safety and Effectiveness of Passeo-18 Lux Drug-Coated Balloon Catheter in Infrainguinal Endovascular Revascularization in the Korean Population: A Multicenter Post-Market Surveillance Study},
journal = {Korean Journal of Radiology},
year = {2024},
doi = {10.3348/kjr.2024.0099}
}
EUVIMED