Screening for Left Ventricular Dysfunction in Sepsis Using a Smartphone ECG Analysis Application: A Multicenter Validation Study
Journal of Korean Medical Science · 2026
DOI: 10.3346/jkms.2026.41.e217 ↗Kurz gefasst
Multizentrische Studie in der Zeitschrift Journal of Korean Medical Science, 2026. Verfasst von Yun Seong Park und 7 weiteren Autor:innen. Beteiligte Einrichtung: Department of Emergency Medicine, Seoul National University College of Medicine, Seoul, Korea. Hauptthemen laut MEDLINE: Ventricular Dysfunction, Left, Electrocardiography, Smartphone, Sepsis. Die Arbeit nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Korea Health Industry Development Institute, SNUBH Research Fund.
Themen: Sepsis
Abstract (Originalsprache)
BACKGROUND: Sepsis-induced left ventricular (LV) dysfunction complicates fluid resuscitation, increasing the risk of pulmonary edema and worsening outcomes. Echocardiographic assessment is often delayed, and natriuretic peptides such as N-terminal pro-B-type natriuretic peptide (NT-proBNP) have limited diagnostic accuracy in this setting. We evaluated a smartphone-based electrocardiogram (ECG) analysis application for screening LV dysfunction in patients with sepsis. METHODS: In this multicenter retrospective observational study, we included 425 adult sepsis patients from three university hospitals who underwent both a 12-lead ECG and transthoracic echocardiography within 72 hours of emergency department admission. ECG images displayed on a monitor were photographed and analyzed using an artificial intelligence (AI)-based smartphone application (ECG Buddy™), which generated a quantitative digital biomarker for LV dysfunction (quantitative electrocardiogram scores for LV dysfunction [QCG-LVDys]). LV dysfunction was defined as a left ventricular ejection fraction ≤ 40%. The diagnostic performance of QCG-LVDys for detecting LV dysfunction was evaluated using area under the receiver operating characteristic curve (ROC-AUC). A predefined comparison with NT-proBNP was performed in the single center where NT-proBNP was routinely measured. RESULTS: In the overall multicenter cohort, QCG-LVDys showed high diagnostic performance for LV dysfunction, with an ROC-AUC of 0.901. Using an optimized threshold (37.35), QCG-LVDys achieved a sensitivity of 89.6%, specificity of 75.1%, and negative predictive value (NPV) of 97.5%. In the NT-proBNP subset, QCG-LVDys outperformed NT-proBNP (ROC-AUC 0.911 vs. 0.637, P < 0.001). Higher QCG-LVDys values were associated with increased lactate levels (P = 0.002) and 28-day in-hospital mortality (P < 0.001). CONCLUSION: AI-driven ECG analysis via a smartphone app provided a rapid, accessible, and accurate screening tool for LV dysfunction in sepsis and outperformed NT-proBNP. Its high NPV suggests potential utility for early risk stratification and for informing cautious hemodynamic management, although prospective studies are needed to define its role in sepsis treatment protocols.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Emergency Medicine, Seoul National University College of Medicine, Seoul, Korea.
- Department of Emergency Medicine, Armed Forces Capital Hospital, Seongnam, Korea.
- Department of Emergency Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
- ARPI Inc., Seongnam, Korea.
- Department of Emergency Medicine, Seoul Metropolitan Government-Seoul National University Boramae Medical Center, Seoul, Korea.
- Cardiovascular Center, Department of Internal Medicine, Seoul National University Bundang Hospital, Seongnam, Korea.
ORCID-Profile: Yun Seong Park, Joonghee Kim, You Hwan Jo, Woon Yong Kwon, Kyoung Jun Song, Hui Jai Lee, Youngjin Cho, Ji Eun Hwang
Förderung
- Korea Health Industry Development Institute
- SNUBH Research Fund
Zitieren
APA
Park, Y. S., Kim, J., Jo, Y. H., Kwon, W. Y., Song, K. J., Lee, H. J., Cho, Y., & Hwang, J. E. (2026). Screening for Left Ventricular Dysfunction in Sepsis Using a Smartphone ECG Analysis Application: A Multicenter Validation Study. Journal of Korean Medical Science. https://doi.org/10.3346/jkms.2026.41.e217
Vancouver
Park YS, Kim J, Jo YH, Kwon WY, Song KJ, Lee HJ, et al. Screening for Left Ventricular Dysfunction in Sepsis Using a Smartphone ECG Analysis Application: A Multicenter Validation Study. Journal of Korean Medical Science. 2026. doi:10.3346/jkms.2026.41.e217
BibTeX
@article{Park2026,
author = {Park, Yun Seong and Kim, Joonghee and Jo, You Hwan and Kwon, Woon Yong and Song, Kyoung Jun and Lee, Hui Jai and Cho, Youngjin and Hwang, Ji Eun},
title = {Screening for Left Ventricular Dysfunction in Sepsis Using a Smartphone ECG Analysis Application: A Multicenter Validation Study},
journal = {Journal of Korean Medical Science},
year = {2026},
doi = {10.3346/jkms.2026.41.e217}
}