Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice
Journal of Korean Medical Science · 2023 · 38 (5)
DOI: 10.3346/jkms.2023.38.e34 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Korean Medical Science, 2023. Verfasst von Joo Myung Lee und 30 weiteren Autor:innen. Beteiligte Einrichtung: Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, …. Hauptthemen laut MEDLINE: Drug-Eluting Stents, Percutaneous Coronary Intervention, Thrombosis, Coronary Artery Disease. Die Arbeit wurde bisher 3-mal zitiert (Crossref) und nennt 36 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
BACKGROUND: The risk of device thrombosis and device-oriented clinical outcomes with bioresorbable vascular scaffold (BVS) was reported to be significantly higher than with contemporary drug-eluting stents (DESs). However, optimal device implantation may improve clinical outcomes in patients receiving BVS. The current study evaluated mid-term safety and efficacy of Absorb BVS with meticulous device optimization under intravascular imaging guidance. METHODS: The SMART-REWARD and PERSPECTIVE-PCI registries in Korea prospectively enrolled 390 patients with BVS and 675 patients with DES, respectively. The primary endpoint was target vessel failure (TVF) at 2 years and the secondary major endpoint was patient-oriented composite outcome (POCO) at 2 years. RESULTS: Patient-level pooled analysis evaluated 1,003 patients (377 patients with BVS and 626 patients with DES). Mean scaffold diameter per lesion was 3.24 ± 0.30 mm in BVS group. Most BVSs were implanted with pre-dilatation (90.9%), intravascular imaging guidance (74.9%), and post-dilatation (73.1%) at proximal to mid segment (81.9%) in target vessel. Patients treated with BVS showed comparable risks of 2-year TVF (2.9% vs. 3.7%, adjusted hazard ratio [HR], 1.283, 95% confidence interval [CI], 0.487-3.378, P = 0.615) and 2-year POCO (4.5% vs. 5.9%, adjusted HR, 1.413, 95% CI, 0.663-3.012, P = 0.370) than those with DES. The rate of 2-year definite or probable device thrombosis (0.3% vs. 0.5%, P = 0.424) was also similar. The sensitivity analyses consistently showed comparable risk of TVF and POCO between the 2 groups. CONCLUSION: With meticulous device optimization under imaging guidance and avoidance of implantation in small vessels, BVS showed comparable risks of 2-year TVF and device thrombosis with DES. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT02601404, NCT04265443.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Division of Cardiology, Department of Medicine, Heart Vascular Stroke Institute, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul, Korea.
- Division of Cardiology, Department of Internal Medicine, Chungnam National University Hospital, Chungnam National University College of Medicine, Daejeon, Korea.
- Division of Cardiology, Department of Internal Medicine, Kangbuk Samsung Hospital, Sungkyunkwan University School of Medicine, Seoul, Korea.
- Division of Cardiology, Department of Internal Medicine, Bucheon Sejong Hospital, Bucheon, Korea.
- Division of Cardiology, Department of Internal Medicine, Jeonbuk National University Hospital and Jeonbuk National University Medical School, Jeonju, Korea.
- Division of Cardiology, Department of Internal Medicine, Keimyung University Dongsan Hospital, Daegu, Korea.
ORCID-Profile: Joo Myung Lee, Hyun Sung Joh, Ki Hong Choi, David Hong, Taek Kyu Park, Jeong Hoon Yang, Young Bin Song, Jin-Ho Choi, Seung-Hyuk Choi, Jin-Ok Jeong, Jong-Young Lee, Young Jin Choi, Jei-Keon Chae, Seung-Ho Hur, Jang-Whan Bae, Ju-Hyeon Oh, Kook-Jin Chun, Hyun-Joong Kim, Byung Ryul Cho, Doosup Shin, Seung Hun Lee, Doyeon Hwang, Hyun-Jong Lee, Ho-Jun Jang, Hyun Kuk Kim, Sang Jin Ha, Eun-Seok Shin, Joon-Hyung Doh, Joo-Yong Hahn, Hyeon-Cheol Gwon
Zitieren
APA
Lee, J. M., Joh, H. S., Choi, K. H., Hong, D., Park, T. K., Yang, J. H., Song, Y. B., Choi, J. H., Choi, S. H., Jeong, J. O., Lee, J. Y., Choi, Y. J., Chae, J. K., Hur, S. H., Bae, J. W., Oh, J. H., Chun, K. J., Kim, H. J., Cho, B. R., …, & SMART-REWARD Investigators (2023). Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice. Journal of Korean Medical Science, 38(5). https://doi.org/10.3346/jkms.2023.38.e34
Vancouver
Lee JM, Joh HS, Choi KH, Hong D, Park TK, Yang JH, et al. Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice. Journal of Korean Medical Science. 2023;38(5). doi:10.3346/jkms.2023.38.e34
BibTeX
@article{Lee2023,
author = {Lee, Joo Myung and Joh, Hyun Sung and Choi, Ki Hong and Hong, David and Park, Taek Kyu and Yang, Jeong Hoon and Song, Young Bin and Choi, Jin-Ho and Choi, Seung-Hyuk and Jeong, Jin-Ok and Lee, Jong-Young and Choi, Young Jin and Chae, Jei-Keon and Hur, Seung-Ho and Bae, Jang-Whan and Oh, Ju-Hyeon and Chun, Kook-Jin and Kim, Hyun-Joong and Cho, Byung Ryul and Shin, Doosup and Lee, Seung Hun and Hwang, Doyeon and Lee, Hyun-Jong and Jang, Ho-Jun and Kim, Hyun Kuk and Ha, Sang Jin and Shin, Eun-Seok and Doh, Joon-Hyung and Hahn, Joo-Yong and Gwon, Hyeon-Cheol and SMART-REWARD Investigators, SMART-REWARD Investigators},
title = {Safety and Efficacy of Everolimus-Eluting Bioresorbable Vascular Scaffold Versus Second-Generation Drug-Eluting Stents in Real-World Practice},
journal = {Journal of Korean Medical Science},
year = {2023},
volume = {38},
number = {5},
doi = {10.3346/jkms.2023.38.e34}
}
EUVIMED