Radiation safety for pain physicians: principles and recommendations
The Korean Journal of Pain · 01.04.2022 · 35 (2) · 129-139
DOI: 10.3344/kjp.2022.35.2.129 ↗Kurz gefasst
Übersichtsarbeit in der Zeitschrift The Korean Journal of Pain, erschienen am 01.04.2022. Verfasst von Sewon Park und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine, Seoul, Korea. Die Arbeit wurde bisher 21-mal zitiert (Crossref) und nennt 58 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
C-arm fluoroscopy is a useful tool for interventional pain management. However, with the increasing use of C-arm fluoroscopy, the risk of accumulated radiation exposure is a significant concern for pain physicians. Therefore, efforts are needed to reduce radiation exposure. There are three types of radiation exposure sources: (1) the primary X-ray beam, (2) scattered radiation, and (3) leakage from the X-ray tube. The major radiation exposure risk for most medical staff members is scattered radiation, the amount of which is affected by many factors. Pain physicians can reduce their radiation exposure by use of several effective methods, which utilize the following main principles: reducing the exposure time, increasing the distance from the radiation source, and radiation shielding. Some methods reduce not only the pain physician's but also the patient's radiation exposure. Taking images with collimation and minimal use of magnification are ways to reduce the intensity of the primary X-ray beam and the amount of scattered radiation. It is also important to carefully select the C-arm fluoroscopy mode, such as pulsed mode or low-dose mode, for ensuring the physician's and patient's radiation safety. Pain physicians should practice these principles and also be aware of the annual permissible radiation dose as well as checking their radiation exposure. This article aimed to review the literature on radiation safety in relation to C-arm fluoroscopy and provide recommendations to pain physicians during C-arm fluoroscopy-guided interventional pain management.
Schlagwörter
Stichwörter der Autor:innen
Autor:innen und Institutionen
- Department of Anesthesiology and Pain Medicine, Konkuk University School of Medicine, Seoul, Korea.
ORCID-Profile: Sewon Park, Minjung Kim, Jae Hun Kim
Zitieren
APA
Park, S., Kim, M., & Kim, J. H. (2022). Radiation safety for pain physicians: principles and recommendations. The Korean Journal of Pain, 35(2), 129-139. https://doi.org/10.3344/kjp.2022.35.2.129
Vancouver
Park S, Kim M, Kim JH. Radiation safety for pain physicians: principles and recommendations. The Korean Journal of Pain. 2022;35(2):129-139. doi:10.3344/kjp.2022.35.2.129
BibTeX
@article{Park2022,
author = {Park, Sewon and Kim, Minjung and Kim, Jae Hun},
title = {Radiation safety for pain physicians: principles and recommendations},
journal = {The Korean Journal of Pain},
year = {2022},
volume = {35},
number = {2},
pages = {129--139},
doi = {10.3344/kjp.2022.35.2.129}
}
EUVIMED