Analytical Performance Specifications Derived from External Quality Assessment Data: Comparison with Biological Variation-Based Models for Intermediate Precision Assessment

Claudio Ilardo iD, Emmanuel Reynaud iD, Nathalie Benaily iD

Annals of Laboratory Medicine · 07.08.2026

DOI: 10.3343/alm.2026.0092 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Laboratory Medicine, online erschienen am 07.08.2026. Verfasst von Claudio Ilardo und 2 weiteren Autor:innen. Beteiligte Einrichtung: INOVIE LABOSUD Laboratory (Inovie member), Montpellier, France.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Analytical performance specifications (APSs) are essential for quality management in medical laboratories. Considering the discrepancies between laboratory performance and existing guidelines, lack of consideration of concentration-dependent variability, and absence of recommendations for certain parameters, we aimed to define APSs for internal use in biochemistry, hemostasis, and hematology based on external quality assessment (EQA) peer group data and evaluate their suitability for intermediate precision assessment versus biological variation (BV)-based APSs. Methods: across laboratories and (ii) observed analytical imprecision expressed as a percentage of the allowable imprecision budget.

Results

APSs were established for 110 biochemical analytes, 23 hemostasis parameters, and 28 hematology parameters across different concentration ranges. EQA-derived APSs agreed with observed intermediate precision for 102 biochemical, 14 hemostasis, and 24 hematology parameters. BV-based APSs showed agreement for only 49 biochemical, two hemostasis, and 11 hematology parameters, while overly restrictive goals or lack of agreement were observed for several analytes.

Conclusions

APSs derived from pooled EQA peer group data provide realistic and technically achievable intermediate precision targets consistent with current AP and thus can complement BV-based specifications.

Schlagwörter

Stichwörter der Autor:innen

Analytical performance specificationBiochemistryBiological variationCoefficient variationHematologyHemostasisState of the art

Autor:innen und Institutionen

  • INOVIE LABOSUD Laboratory (Inovie member), Montpellier, France.
  • INOVIE BIOAXIOME Laboratory (Inovie member), Nîmes, France.
  • INOVIE BIOFUTUR Laboratory (Inovie member), Paris, France.

ORCID-Profile: Claudio Ilardo, Emmanuel Reynaud, Nathalie Benaily

Zitieren

APA

Ilardo, C., Reynaud, E., & Benaily, N. (2026). Analytical Performance Specifications Derived from External Quality Assessment Data: Comparison with Biological Variation-Based Models for Intermediate Precision Assessment. Annals of Laboratory Medicine. https://doi.org/10.3343/alm.2026.0092

Vancouver

Ilardo C, Reynaud E, Benaily N. Analytical Performance Specifications Derived from External Quality Assessment Data: Comparison with Biological Variation-Based Models for Intermediate Precision Assessment. Annals of Laboratory Medicine. 2026. doi:10.3343/alm.2026.0092

BibTeX
@article{Ilardo2026,
  author = {Ilardo, Claudio and Reynaud, Emmanuel and Benaily, Nathalie},
  title = {Analytical Performance Specifications Derived from External Quality Assessment Data: Comparison with Biological Variation-Based Models for Intermediate Precision Assessment},
  journal = {Annals of Laboratory Medicine},
  year = {2026},
  doi = {10.3343/alm.2026.0092}
}
Kostenlos starten →