EUVIMEDEUVIMED entdecken
Crossref

Patient-Based Real-Time Quality Control for Semiquantitative Tests Based on Hierarchical Differences

Yuanyuan Li iD, Xiaoling Chen iD, Ying Zhao iD

Annals of Laboratory Medicine · 06.08.2026

DOI: 10.3343/alm.2026.0055 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Laboratory Medicine, online erschienen am 06.08.2026. Verfasst von Yuanyuan Li und 2 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China. Gefördert von: Natural Science Foundation of China of Zhejiang Province.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

With developments in artificial intelligence, patient-based real-time quality control (PBRTQC) has advanced. However, its application to semiquantitative tests remains unreported. Taking urine protein (URP), a semiquantitative parameter in routine urinalysis, as an example, we explored the application of PBRTQC in semiquantitative tests.

Methods

We assessed the correlation between URP and the quantitative parameter, urine total protein (UTP). Measurement results for both analytes were classified into five grades to calculate hierarchical differences (HDs). Three HD-based algorithms were established: the moving rate of inconsistency (MRI), moving average of HDs (MAHD), and moving average of absolute HDs (MAAD). Their performance was compared with that of the moving rate of positive results (MRP) using computer simulations to evaluate the detection of systematic errors (SEs) and random errors (REs). Anti-interference capability was evaluated by rearranging the sample sequence.

Results

The MRP method detected SEs but failed to monitor REs. Compared with MRP, HD-based algorithms reduced the median number of patients affected before detection at critical errors by 83.1% for SEs and by 94.2% for REs. MRI, MAHD and MAAD showed significantly improved detection capabilities for SEs and, particularly, REs. Regarding anti-interference, rearranging the sample sequence significantly deteriorated MRP performance, whereas the HD-based algorithms remained unaffected and stable.

Conclusions

The novel HD-based algorithms demonstrate superior error detection and anti-interference capabilities compared with MRP. This study provides an effective PBRTQC strategy for semiquantitative tests by leveraging related quantitative data.

Schlagwörter

Stichwörter der Autor:innen

Internal quality controlMoving averageMoving rate of positive resultsPatient-based real-time quality controlQuality managementSemiquantitative testsUrine protein

Autor:innen und Institutionen

  • Department of Laboratory Medicine, The First Affiliated Hospital, Zhejiang University School of Medicine, Hangzhou, China.
  • Zhejiang Key Laboratory of Clinical In Vitro Diagnostic Techniques, Hangzhou, China.
  • Institute of Laboratory Medicine, Zhejiang University, Hangzhou, China.

ORCID-Profile: Yuanyuan Li, Xiaoling Chen, Ying Zhao

Förderung

  • Natural Science Foundation of China of Zhejiang Province

Zitieren

APA

Li, Y., Chen, X., & Zhao, Y. (2026). Patient-Based Real-Time Quality Control for Semiquantitative Tests Based on Hierarchical Differences. Annals of Laboratory Medicine. https://doi.org/10.3343/alm.2026.0055

Vancouver

Li Y, Chen X, Zhao Y. Patient-Based Real-Time Quality Control for Semiquantitative Tests Based on Hierarchical Differences. Annals of Laboratory Medicine. 2026. doi:10.3343/alm.2026.0055

BibTeX
@article{Li2026,
  author = {Li, Yuanyuan and Chen, Xiaoling and Zhao, Ying},
  title = {Patient-Based Real-Time Quality Control for Semiquantitative Tests Based on Hierarchical Differences},
  journal = {Annals of Laboratory Medicine},
  year = {2026},
  doi = {10.3343/alm.2026.0055}
}
Kostenlos starten →