Kogene PowerChek Multiplex Real-time PCR Kits Versus the BioFire FilmArray Gastrointestinal Panel: Roles of Crossing Point Values and Melting Curves in Interpreting the FilmArray Gastrointestinal Panel
Annals of Laboratory Medicine · 2025
DOI: 10.3343/alm.2025.0047 ↗Kurz gefasst
Vergleichsstudie in der Zeitschrift Annals of Laboratory Medicine, 2025. Verfasst von In Young Yoo und 5 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea. Hauptthemen laut MEDLINE: Real-Time Polymerase Chain Reaction, Multiplex Polymerase Chain Reaction, Reagent Kits, Diagnostic. Die Arbeit wurde bisher 7-mal zitiert (Crossref) und nennt 17 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Samkwang Medical Lab.
Abstract (Originalsprache)
Background
Various molecular methods are used to rapidly detect gastrointestinal pathogens, highlighting the importance of understanding the performance of the associated kits in detail. We comprehensively assessed the performance of Kogene PowerChek multiplex real-time PCR kits (PowerChek Bacterial/Viral Kits) with the FilmArray GI Panel.
Methods
Residual stool specimens (N=246), initially tested utilizing the FilmArray GI Panel (May 2023-Jan 2024), were reanalyzed using PowerChek Bacterial/Viral Kits. Discrepancies were resolved by performing additional molecular assays and reviewing culture results when available. True positives (TPs)/true negatives were defined by concordant results in at least two assays. We determined cycle threshold (Ct)/crossing point (Cp) distributions between the TP and false positive (FP) groups and analyzed melting curves for the FilmArray GI Panel FPs.
Results
The positive-percent agreement (PPA) of the PowerChek Bacterial/Viral Kits was 50-100%, with lower values for Salmonella spp., rotavirus, and astrovirus, whereas the FilmArray GI Panel showed 100% PPA across all targets. Both platforms demonstrated >99% negative-percent agreement, except for enteropathogenic Escherichia coli (EPEC) and adenovirus (PowerChek Bacterial/Viral Kits) or EPEC, enteroaggregative E. coli, norovirus, and Salmonella spp. (FilmArray GI Panel). The FPs showed higher Ct/Cp values with both kits, and these values were significantly higher for adenovirus (PowerChek Viral Kit), EPEC, and norovirus (FilmArray GI Panel). Melting curve analysis of four norovirus FPs (FilmArray GI Panel) revealed atypical patterns in three cases.
Conclusions
The FilmArray GI Panel demonstrated higher sensitivity than the PowerChek Kits. For norovirus, melting curve analysis will help avoid FPs.
Schlagwörter
MeSH-Schlagwörter (MEDLINE)
Stichwörter der Autor:innen
Substanzen
Autor:innen und Institutionen
- Department of Laboratory Medicine, Seoul St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Department of Laboratory Medicine, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Infectious Disease Laboratory Research Center, Eunpyeong St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Department of Laboratory Medicine, College of Medicine, The Catholic University of Korea, Seoul, Korea.
- Department of Laboratory Medicine, Uijeongbu St. Mary's Hospital, College of Medicine, The Catholic University of Korea, Seoul, Korea.
ORCID-Profile: In Young Yoo, Sungjin Jo, Joo An Kwon, Jay Ho Han, Hae Kyung Lee, Yeon-Joon Park
Förderung
- Samkwang Medical Lab
Zitieren
APA
Yoo, I. Y., Jo, S., Kwon, J. A., Han, J. H., Lee, H. K., & Park, Y. J. (2025). Kogene PowerChek Multiplex Real-time PCR Kits Versus the BioFire FilmArray Gastrointestinal Panel: Roles of Crossing Point Values and Melting Curves in Interpreting the FilmArray Gastrointestinal Panel. Annals of Laboratory Medicine. https://doi.org/10.3343/alm.2025.0047
Vancouver
Yoo IY, Jo S, Kwon JA, Han JH, Lee HK, Park YJ. Kogene PowerChek Multiplex Real-time PCR Kits Versus the BioFire FilmArray Gastrointestinal Panel: Roles of Crossing Point Values and Melting Curves in Interpreting the FilmArray Gastrointestinal Panel. Annals of Laboratory Medicine. 2025. doi:10.3343/alm.2025.0047
BibTeX
@article{Yoo2025,
author = {Yoo, In Young and Jo, Sungjin and Kwon, Joo An and Han, Jay Ho and Lee, Hae Kyung and Park, Yeon-Joon},
title = {Kogene PowerChek Multiplex Real-time PCR Kits Versus the BioFire FilmArray Gastrointestinal Panel: Roles of Crossing Point Values and Melting Curves in Interpreting the FilmArray Gastrointestinal Panel},
journal = {Annals of Laboratory Medicine},
year = {2025},
doi = {10.3343/alm.2025.0047}
}
EUVIMED