EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Comparison of Direct and Extraction Immunoassay Methods With Liquid Chromatography-Tandem Mass Spectrometry Measurement of Urinary Free Cortisol for the Diagnosis of Cushing’s Syndrome

Danni Mu iD, Jiadan Fang iD, Songlin Yu iD, Yichen Ma iD, Jin Cheng iD, Yingying Hu iD, Ailing Song iD, Fang Zhao iD, Qi Zhang iD, Zhihong Qi iD, Kui Zhang iD, Liangyu Xia iD und 3 weitere

Annals of Laboratory Medicine · 2024

DOI: 10.3343/alm.2024.44.1.29 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Annals of Laboratory Medicine, 2024. Verfasst von Danni Mu und 14 weiteren Autor:innen. Beteiligte Einrichtung: Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Science, Beijin…. Hauptthemen laut MEDLINE: Cushing Syndrome. Die Arbeit wurde bisher 4-mal zitiert (Crossref) und nennt 25 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: National High Level Hospital Clinical.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Twenty-four-hour urinary free cortisol (UFC) measurement is the initial diagnostic test for Cushing's syndrome (CS). We compared UFC determination by both direct and extraction immunoassays using Abbott Architect, Siemens Atellica Solution, and Beckman DxI800 with liquid chromatography-tandem mass spectrometry (LC-MS/MS). In addition, we evaluated the value of 24-hr UFC measured by six methods for diagnosing CS.

Methods

Residual 24-hr urine samples of 94 CS and 246 non-CS patients were collected. A laboratory-developed LC-MS/MS method was used as reference. UFC was measured by direct assays (D) using Abbott, Siemens, and Beckman platforms and by extraction assays (E) using Siemens and Beckman platforms. Method was compared using Passing-Bablok regression and Bland-Altman plot analyses. Cut-off values for the six assays and corresponding sensitivities and specificities were calculated by ROC analysis.

Results

Abbott-D, Beckman-E, Siemens-E, and Siemens-D showed strong correlations with LC-MS/MS (Spearman coefficient r=0.965, 0.922, 0.922, and 0.897, respectively), while Beckman-D showed weaker correlation (r=0.755). All immunoassays showed proportionally positive bias. The areas under the curve were 0.975 for Abbott-D, 0.972 for LC-MS/MS, 0.966 for Siemens-E, 0.948 for Siemens-D, 0.955 for Beckman-E, and 0.877 for Beckman-D. The cut-off values varied significantly (154.8-1,321.5 nmol/24 hrs). Assay sensitivity and specificity ranged from 76.1% to 93.2% and from 93.0% to 97.1%, respectively.

Conclusions

Commercially available immunoassays for measuring UFC show different levels of analytical consistency compared to LC-MS/MS. Abbott-D, Siemens-E, and Beckman-E have high diagnostic accuracy for CS.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Cushing SyndromeHumansHydrocortisoneChromatography, LiquidTandem Mass SpectrometryImmunoassayThiophenesUrea

Stichwörter der Autor:innen

Cushing’s syndromeImmunoassayLiquid chromatography-tandem mass spectrometryMethod comparisonUrinary free cortisol

Substanzen

HydrocortisoneN-(2,6-diethylphenyl)-N'-(3-(2-methylphenyl)-6,7-dihydro-5H-cyclopenta(f)(l)benzothiophen-2-yl)ureaThiophenesUrea

Autor:innen und Institutionen

  • Department of Laboratory Medicine, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Science, Beijing, China.
  • State Key Laboratory of Complex Severe and Rare Diseases, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Science, Beijing, China.
  • Department of Endocrinology, Peking Union Medical College Hospital, Peking Union Medical College and Chinese Academy of Medical Science, Beijing, China.

ORCID-Profile: Danni Mu, Jiadan Fang, Songlin Yu, Yichen Ma, Jin Cheng, Yingying Hu, Ailing Song, Fang Zhao, Qi Zhang, Zhihong Qi, Kui Zhang, Liangyu Xia, Ling Qiu, Huijuan Zhu, Xinqi Cheng

Förderung

  • National High Level Hospital Clinical

Zitieren

APA

Mu, D., Fang, J., Yu, S., Ma, Y., Cheng, J., Hu, Y., Song, A., Zhao, F., Zhang, Q., Qi, Z., Zhang, K., Xia, L., Qiu, L., Zhu, H., & Cheng, X. (2024). Comparison of Direct and Extraction Immunoassay Methods With Liquid Chromatography-Tandem Mass Spectrometry Measurement of Urinary Free Cortisol for the Diagnosis of Cushing’s Syndrome. Annals of Laboratory Medicine. https://doi.org/10.3343/alm.2024.44.1.29

Vancouver

Mu D, Fang J, Yu S, Ma Y, Cheng J, Hu Y, et al. Comparison of Direct and Extraction Immunoassay Methods With Liquid Chromatography-Tandem Mass Spectrometry Measurement of Urinary Free Cortisol for the Diagnosis of Cushing’s Syndrome. Annals of Laboratory Medicine. 2024. doi:10.3343/alm.2024.44.1.29

BibTeX
@article{Mu2024,
  author = {Mu, Danni and Fang, Jiadan and Yu, Songlin and Ma, Yichen and Cheng, Jin and Hu, Yingying and Song, Ailing and Zhao, Fang and Zhang, Qi and Qi, Zhihong and Zhang, Kui and Xia, Liangyu and Qiu, Ling and Zhu, Huijuan and Cheng, Xinqi},
  title = {Comparison of Direct and Extraction Immunoassay Methods With Liquid Chromatography-Tandem Mass Spectrometry Measurement of Urinary Free Cortisol for the Diagnosis of Cushing’s Syndrome},
  journal = {Annals of Laboratory Medicine},
  year = {2024},
  doi = {10.3343/alm.2024.44.1.29}
}
Kostenlos starten →