EUVIMEDEUVIMED entdecken
Crossref

Use of Novel Digital X-ray Device Reduces Radiation Exposure, Imaging Costs, and Work Related Injury in the Emergency Department

Ashley Conner, Jesua I Law

Global Journal of Critical Care and Emergency Medicine · 2025

DOI: 10.33425/3065-5641.1018 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Global Journal of Critical Care and Emergency Medicine, 2025. Verfasst von Ashley Conner und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Emergency departments (EDs) depend on rapid, reliable radiography. However, conventional mobile X-ray units are often heavy and cumbersome, can contribute to delays in bedside imaging, and are associated with an increased risk of operator musculoskeletal injury. Despite advances in digital radiography, positioning and exposure errors still drive meaningful retake rates, adding avoidable ionizing-radiation exposure and cost; when each exam carries a material per-study cost, repeat imaging accumulates quickly.

Objective

To address common ED pain points—unnecessary radiation from retakes, ergonomic burden, and direct imaging costs—by evaluating a handheld, low-output system capable of digital radiography (DR), dynamic digital radiography (DDR), and fluoroscopy. Approach: We describe the implementation of the OXOS MC2 handheld X-ray system in the ED and its design features intended to improve timeliness and safety: compact form factor; low radiation output with small scatter; and alignment safeguards (“no-fire” positioning) to reduce mis-framing and exposure errors. The system can be operated by trained ED personnel under appropriate supervision and local policy, aiming to alleviate technologist bottlenecks during peak demand. Significance: In time-critical settings, every minute from order to first image matters for triage and disposition. By bringing DR/DDR/fluoroscopy directly to the bedside and reducing repeat acquisitions, decreasing cumulative radiation when no truly safe dose threshold has been established, lowering per-episode imaging costs, and mitigating staff injury risk linked to cart transport. The present work discusses ED pitfalls with conventional mobile imaging and outlines how a handheld approach may improve speed and accuracy, reduce wait times, reduce retakes, lower radiation dose, and lower department costs while maintaining diagnostic utility. These findings support broader use of handheld X-ray in emergency care pathways

Zitieren

APA

Conner, A., & Law, J. I. (2025). Use of Novel Digital X-ray Device Reduces Radiation Exposure, Imaging Costs, and Work Related Injury in the Emergency Department. Global Journal of Critical Care and Emergency Medicine. https://doi.org/10.33425/3065-5641.1018

Vancouver

Conner A, Law JI. Use of Novel Digital X-ray Device Reduces Radiation Exposure, Imaging Costs, and Work Related Injury in the Emergency Department. Global Journal of Critical Care and Emergency Medicine. 2025. doi:10.33425/3065-5641.1018

BibTeX
@article{Conner2025,
  author = {Conner, Ashley and Law, Jesua I},
  title = {Use of Novel Digital X-ray Device Reduces Radiation Exposure, Imaging Costs, and Work Related Injury in the Emergency Department},
  journal = {Global Journal of Critical Care and Emergency Medicine},
  year = {2025},
  doi = {10.33425/3065-5641.1018}
}
Kostenlos starten →