EUVIMEDEUVIMED entdecken
Crossref

Dosimetric Comparison of Halcyon vs. TrueBeam Equipment and VMAT vs. Hybrid-IMRT Techniques in Radiotherapy for Bilateral Breast Cancer Treatment

QIU XiBin, Mak KengLok, Mak KinLong, Yeung HoWai, Ho NokHang, Lo HoTing, Kwok KaSan, CHAU MingChun

Radiology & Imaging Journal · 30.09.2025 · 4 (3)

DOI: 10.33425/2835-3587.1036 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Radiology & Imaging Journal, online erschienen am 30.09.2025. Verfasst von QIU XiBin und 7 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objective

The present investigation intends to identify the optimal radiotherapy treatment for synchronous bilateral breast cancer (SBBC) using two RT equipment with two planning techniques.

Methods

A retrospective analysis was conducted on ten consecutive SBBC patients treated at Oncology center of Kiang Wu Hospital. Dosimetric parameters of target volumes and normal tissues were compared across different equipment (Halcyon, TrueBeam) and techniques (VMAT, Hybrid-IMRT). Compliance with RTOG1005 dosimetric constraints was evaluated and statistical differences between techniques were analyzed.

Results

VMAT-Halcyon (VMAT-Hal) demonstrated significantly better target Conformity Index (CI) than HybridIMRT (P=0.02), with no significant difference in Homogeneity Index (HI). Compared to Hybrid-IMRT, VMAT-Hal reduced lung doses, particularly in high-dose regions. VMAT-Hal lowered cardiac V5 (15% vs. 22%, P=0.03) and left anterior descending artery (LAD) dose (10 Gy vs. 14 Gy). Beam-on time with Halcyon was 29% shorter than TrueBeam (2.42 min vs. 3.41 min).

Conclusion

VMAT-Halcyon is the preferred treatment modality that balancing target coverage, normal tissue sparing and treatment efficiency.

Zitieren

APA

XiBin, Q., KengLok, M., KinLong, M., HoWai, Y., NokHang, H., HoTing, L., KaSan, K., & MingChun, C. (2025). Dosimetric Comparison of Halcyon vs. TrueBeam Equipment and VMAT vs. Hybrid-IMRT Techniques in Radiotherapy for Bilateral Breast Cancer Treatment. Radiology & Imaging Journal, 4(3). https://doi.org/10.33425/2835-3587.1036

Vancouver

XiBin Q, KengLok M, KinLong M, HoWai Y, NokHang H, HoTing L, et al. Dosimetric Comparison of Halcyon vs. TrueBeam Equipment and VMAT vs. Hybrid-IMRT Techniques in Radiotherapy for Bilateral Breast Cancer Treatment. Radiology & Imaging Journal. 2025;4(3). doi:10.33425/2835-3587.1036

BibTeX
@article{XiBin2025,
  author = {XiBin, QIU and KengLok, Mak and KinLong, Mak and HoWai, Yeung and NokHang, Ho and HoTing, Lo and KaSan, Kwok and MingChun, CHAU},
  title = {Dosimetric Comparison of Halcyon vs. TrueBeam Equipment and VMAT vs. Hybrid-IMRT Techniques in Radiotherapy for Bilateral Breast Cancer Treatment},
  journal = {Radiology & Imaging Journal},
  year = {2025},
  volume = {4},
  number = {3},
  doi = {10.33425/2835-3587.1036}
}
Kostenlos starten →