EUVIMEDEUVIMED entdecken
Studienprotokoll

To Assess the Effect of BMI on Patient Setup Reproducibility in Hypofractionation of Breast Cancer to Establish an Imaging Protocol

Zaheeda Mulla, Rania Hashem, Hiba Taha, Maria Coogen, Majd Alharthy, Hussam Hijazi

International Journal of Research in Oncology · 2023

DOI: 10.33425/2833-0390.1015 ↗

Kurz gefasst

Studienprotokoll in der Zeitschrift International Journal of Research in Oncology, 2023. Verfasst von Zaheeda Mulla und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Objectives

To analyze the setup accuracy among patients treated for breast cancer with hypofractionation radiation therapy (HFRT) regimen (five fractions instead of 15-16 fractions in standard regimen) and predict the necessity of performing the setup imaging in the 4th and 5th fractions as a function of setup accuracy in the first three fractions.

Methods

This retrospective study reviewed setup displacements in each direction (lateral, longitudinal, and vertical) for 51 women with breast cancer treated with HFRT at the Radiation Therapy Unit between September 2020 and May 2022. Besides the five fractions (#1– # 5), the mean setup error was computed for the first three fractions (AVG-III) for each direction. Setup accuracy rates were computed for each direction and fraction as the percentage of fractions with setup error ≤ 0.5 cm. The correlations of #1, #2, #3, and AVG-III setup errors and their value in indicating #4 and #5 setup error and accuracy were analyzed using Pearson's coefficient and Receiver Operating Characteristics (ROC) curve, respectively. Furthermore, the effect of body mass index (BMI) on setup reproducibility was analyzed using logistic regression Result: The mean (SD) age of the participants was 54.41 (11.46) years. There was a high percentage of overweight (25.5%) and obese (53.0%). The mean setup error was 0.05) and #5 (r = -0.128–0.254; p>0.05) within any of the first three fractions or AVG-III, in any of the directions. In the ROC curve, only #5 accuracy was indicated by #3 in the longitudinal direction (AUC=0.89, p=0.025). BMI was only associated with inaccurate setup for fraction #3 in the lateral direction, in a positive relationship (OR=1.15, 95% CI = 1.01–1.30; p=0.031).

Conclusion

Setup accuracy in the first fractions of HFRT does not predict accuracy in the two last fractions nor is predicted by the patient’s BMI. Consequently, women with breast cancer treated with HFRT require daily imaging for optimal setup before each radiotherapy fraction.

Zitieren

APA

Mulla, Z., Hashem, R., Taha, H., Coogen, M., Alharthy, M., & Hijazi, H. (2023). To Assess the Effect of BMI on Patient Setup Reproducibility in Hypofractionation of Breast Cancer to Establish an Imaging Protocol. International Journal of Research in Oncology. https://doi.org/10.33425/2833-0390.1015

Vancouver

Mulla Z, Hashem R, Taha H, Coogen M, Alharthy M, Hijazi H. To Assess the Effect of BMI on Patient Setup Reproducibility in Hypofractionation of Breast Cancer to Establish an Imaging Protocol. International Journal of Research in Oncology. 2023. doi:10.33425/2833-0390.1015

BibTeX
@article{Mulla2023,
  author = {Mulla, Zaheeda and Hashem, Rania and Taha, Hiba and Coogen, Maria and Alharthy, Majd and Hijazi, Hussam},
  title = {To Assess the Effect of BMI on Patient Setup Reproducibility in Hypofractionation of Breast Cancer to Establish an Imaging Protocol},
  journal = {International Journal of Research in Oncology},
  year = {2023},
  doi = {10.33425/2833-0390.1015}
}
Kostenlos starten →