Operational Optimization of HVAC Performance in Hot–Humid Climate: Minute-Level Case Study of an Institutional Building in Bangkok, Thailand
International Journal of Innovations in Science and Technology · 12.01.2026 · 115
DOI: 10.33411/ijist/1753 ↗Kurz gefasst
Fachartikel in der Zeitschrift International Journal of Innovations in Science and Technology, online erschienen am 12.01.2026. Verfasst von Muhammad Fawad Saleem und 5 weiteren Autor:innen. Die Arbeit nennt 46 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).
Abstract (Originalsprache)
Operational efficiency is one of the fundamental factors that determine the energy performance of buildings in terms of their ability to maintain thermal comfort. This research aims to evaluate operational HVAC characteristics such as cooling loads, energy intensity, and thermal comfort in an institutional building in Bangkok, Thailand. The building has seven floors with 33 zones. This study utilizes minute-level electricity consumption and indoor environmental conditions to determine operational efficiency. The study found significant underutilization of operational HVAC systems in buildings. The load factor of the building is 26.0%, indicating that some parts of the building consume 4.5 times more energy than the zone with the lowest consumption. The thermal comfort of the building is only 60.6%, indicating that there is significant overcooling in buildings. The research has also found that there is no significant relationship between outside temperatures and energy consumption in buildings (R² = 0.023). The research has proposed several strategies that could potentially reduce peak demand by 12.8% while improving thermal comfort by 15%, without requiring any upgrades to HVAC equipment.
Zitieren
APA
Saleem, M. F., Baseer, M., Imtiaz, S. A., Fawaz, M., Shoukat, S., & Fayyaz, N. (2026). Operational Optimization of HVAC Performance in Hot–Humid Climate: Minute-Level Case Study of an Institutional Building in Bangkok, Thailand. International Journal of Innovations in Science and Technology, 115. https://doi.org/10.33411/ijist/1753
Vancouver
Saleem MF, Baseer M, Imtiaz SA, Fawaz M, Shoukat S, Fayyaz N. Operational Optimization of HVAC Performance in Hot–Humid Climate: Minute-Level Case Study of an Institutional Building in Bangkok, Thailand. International Journal of Innovations in Science and Technology. 2026:115. doi:10.33411/ijist/1753
BibTeX
@article{Saleem2026,
author = {Saleem, Muhammad Fawad and Baseer, Majid and Imtiaz, Sardar Ahmed and Fawaz, Muhammad and Shoukat, Sheyar and Fayyaz, Nauman},
title = {Operational Optimization of HVAC Performance in Hot–Humid Climate: Minute-Level Case Study of an Institutional Building in Bangkok, Thailand},
journal = {International Journal of Innovations in Science and Technology},
year = {2026},
pages = {115},
doi = {10.33411/ijist/1753}
}
EUVIMED