EUVIMEDEUVIMED entdecken
Crossref

Loss of the Steep-Axis Flattening Effect in Sutured Clear Corneal Incisions: A Single-Surgeon Vector Analysis

Eun Jung Jung, Yoon Soo Kim, Youngsub Eom, Jong Suk Song, Dong Hyun Kim

Korean Journal of Ophthalmology · 04.11.2026

DOI: 10.3341/kjo.2026.0126 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Korean Journal of Ophthalmology, online erschienen am 04.11.2026. Verfasst von Eun Jung Jung und 4 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, Korea University College of Medicine, Seoul, Republic of Korea.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

Corneal incisions are conventionally assumed to flatten the incision meridian, and steep-axis incision placement has been advocated to reduce pre-existing astigmatism. We aimed to evaluate whether steep-axis clear corneal incisions actually flatten the incision meridian in a single-surgeon series in which the main incisions were closed with a suture.

Methods

This retrospective study analyzed 345 right eyes that underwent phacoemulsification by a single surgeon using superior (100°) or temporal (190°) clear corneal incisions (2.20 or 2.75 mm), each closed with a single 10-0 nylon suture removed at 1 week. Surgically induced astigmatism (SIA) was calculated by vector analysis and decomposed into a flattening component on the incision meridian and a torque component on the orthogonal meridian. The main analysis was focused on steep-axis incisions, defined as a preoperative steep meridian within ±20° of the incision meridian (superior, n = 96; temporal, n = 66).

Results

In steep-axis incisions, the mean flattening effect was negative rather than positive, indicating steepening rather than the intended flattening (superior -0.17 ± 0.56 D, p < 0.001; temporal -0.20 ± 0.73 D, p = 0.059). The perpendicular torque exceeded the flattening effect in all subgroups (superior 0.50 D; temporal 0.40 D), and the SIA meridian deviated from the incision meridian by 52-55° on average. The centroid SIA for the 2.75 mm superior incision was 0.50 D at 41°, consistent across astigmatism types. Individual SIA magnitude was highly variable (0-2.04 D). White-to-white corneal diameter was the only independent biometric predictor of SIA magnitude (β = -0.182, p = 0.027).

Conclusions

In this single-surgeon series of sutured clear corneal incisions, steep-axis incisions did not produce the expected flattening of the incision meridian, and the SIA acted predominantly as torque with a mean steepening effect. Whether the routine suture contributes to this pattern remains to be confirmed by direct sutured-versus-sutureless comparison.

Schlagwörter

Stichwörter der Autor:innen

Alpins methodCataract surgeryClear corneal incisionFlattening effectSurgically induced astigmatismVector analysis

Autor:innen und Institutionen

  • Department of Ophthalmology, Korea University College of Medicine, Seoul, Republic of Korea.
  • YES Eye Clinic, Seoul, Republic of Korea.
  • Department of Ophthalmology, Korea University College of Medicine, Seoul, Republic of Korea. amidfree@gmail.com.

Zitieren

APA

Jung, E. J., Kim, Y. S., Eom, Y., Song, J. S., & Kim, D. H. (2026). Loss of the Steep-Axis Flattening Effect in Sutured Clear Corneal Incisions: A Single-Surgeon Vector Analysis. Korean Journal of Ophthalmology. https://doi.org/10.3341/kjo.2026.0126

Vancouver

Jung EJ, Kim YS, Eom Y, Song JS, Kim DH. Loss of the Steep-Axis Flattening Effect in Sutured Clear Corneal Incisions: A Single-Surgeon Vector Analysis. Korean Journal of Ophthalmology. 2026. doi:10.3341/kjo.2026.0126

BibTeX
@article{Jung2026,
  author = {Jung, Eun Jung and Kim, Yoon Soo and Eom, Youngsub and Song, Jong Suk and Kim, Dong Hyun},
  title = {Loss of the Steep-Axis Flattening Effect in Sutured Clear Corneal Incisions: A Single-Surgeon Vector Analysis},
  journal = {Korean Journal of Ophthalmology},
  year = {2026},
  doi = {10.3341/kjo.2026.0126}
}
Kostenlos starten →