EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

In Vivo Human Lacrimal Gland Imaging Using an Ultrasound Biomicroscopy

Chanjoon Park, Da Ran Kim, Young Chae Yoon, Soonwon Yang, Woong-Joo Whang, Yong-Soo Byun, Hyung Bin Hwang, Kyung Sun Na, Hyun Soo Lee, So Hyang Chung, Eun Chul Kim, Yang Kyung Cho und 2 weitere

Korean Journal of Ophthalmology · 2024

DOI: 10.3341/kjo.2023.0134 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Korean Journal of Ophthalmology, 2024. Verfasst von Chanjoon Park und 13 weiteren Autor:innen. Beteiligte Einrichtung: Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea. Hauptthemen laut MEDLINE: Microscopy, Acoustic, Lacrimal Apparatus. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 8 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

In the present study, we introduce human lacrimal gland imaging using an ultrasound biomicroscopy (UBM) with a soft cover and show their findingsMethods: The representative UBM findings of palpebral lobes in seven subjects (four with non-Sjögren dry eye syndrome, one with Sjögren syndrome, and two healthy subjects) were described in this study. To prolapse the palpebral lobe, the examiner pulled the temporal part of the upper eyelid in the superotemporal direction and directed the subject to look in the inferonasal direction. We scanned the palpebral lobes longitudinally and transversely using UBM. We used an Aviso UBM with a 50 MHz linear probe and ClearScan.

Results

In UBM of two healthy subjects, the echogenicity of the lacrimal gland was lower than that of the sclera and homogeneous. But the parenchyma of a patient with Sjögren dry eye syndrome was quite inhomogeneous compared to the healthy subjects. In two patients with dry eye syndrome, we were able to observe some lobules in the parenchyma. We could find excretory ducts running parallel at the surface of the longitudinal section in some subjects. In the longitudinal UBM scan of a subject, we observed a tubular structure at a depth of 1,500 μm that was considered a blood vessel. It ran from the superonasal to the inferotemporal direction. In a subject, we observed a large cyst beneath the conjunctiva.

Conclusions

Lacrimal gland imaging using UBM has both advantages of optical coherence tomography and sonography, and could be useful for evaluating dry eye syndrome.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Microscopy, AcousticLacrimal ApparatusHumansFemaleMaleMiddle AgedAdultDry Eye SyndromesAgedSjogren's Syndrome

Stichwörter der Autor:innen

Excretory ductsLacrimal glandLobulesParenchymaUltrasound biomicroscopy

Autor:innen und Institutionen

  • Department of Ophthalmology, College of Medicine, The Catholic University of Korea, Seoul, Korea.

Zitieren

APA

Park, C., Kim, D. R., Yoon, Y. C., Yang, S., Whang, W. J., Byun, Y. S., Hwang, H. B., Na, K. S., Lee, H. S., Chung, S. H., Kim, E. C., Cho, Y. K., Kim, H. S., & Hwang, H. (2024). In Vivo Human Lacrimal Gland Imaging Using an Ultrasound Biomicroscopy. Korean Journal of Ophthalmology. https://doi.org/10.3341/kjo.2023.0134

Vancouver

Park C, Kim DR, Yoon YC, Yang S, Whang WJ, Byun YS, et al. In Vivo Human Lacrimal Gland Imaging Using an Ultrasound Biomicroscopy. Korean Journal of Ophthalmology. 2024. doi:10.3341/kjo.2023.0134

BibTeX
@article{Park2024,
  author = {Park, Chanjoon and Kim, Da Ran and Yoon, Young Chae and Yang, Soonwon and Whang, Woong-Joo and Byun, Yong-Soo and Hwang, Hyung Bin and Na, Kyung Sun and Lee, Hyun Soo and Chung, So Hyang and Kim, Eun Chul and Cho, Yang Kyung and Kim, Hyun Seung and Hwang, Hosik},
  title = {In Vivo Human Lacrimal Gland Imaging Using an Ultrasound Biomicroscopy},
  journal = {Korean Journal of Ophthalmology},
  year = {2024},
  doi = {10.3341/kjo.2023.0134}
}
Kostenlos starten →