EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

Comparison of Surgical Outcomes Between Two Modified Yamane Techniques of Scleral Fixation of Intraocular Lenses

Hyewon Jun, Ahran Cho, Joonhong Sohn, Heeyoung Cheong

Journal of the Korean Ophthalmological Society · 15.04.2026 · 67 (4) · 118-130

DOI: 10.3341/jkos.2026.67.4.118 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Journal of the Korean Ophthalmological Society, erschienen am 15.04.2026. Verfasst von Hyewon Jun und 3 weiteren Autor:innen. Die Arbeit nennt 34 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Purpose

To compare the surgical outcomes of two modified Yamane techniques for sutureless scleral fixation of intraocular lenses (IOL): trocar-cannula-based fixation and 26-gauge needle-based fixation.

Methods

A retrospective analysis was conducted on patients who underwent modified Yamane scleral IOL fixation between January 2023 and June 2024 with a minimum follow-up of 6 months. The outcomes assessed included best corrected visual acuity (BCVA), spherical equivalent, astigmatism, astigmatism, and postoperative complications. Measurements were taken preoperatively and at 1 day, 1 week, 1 month, and 6 months after surgery.

Results

Among 86 eyes included, 44 received trocar-cannula-based fixation (trocar group) and 42 received 26-gauge needle-based fixation (needle group). Both groups showed significant improvements in BCVA and spherical equivalent at 6 months postoperatively (BCVA: p = 0.013, p = 0.001; spherical equivalent: p < 0.001, p = 0.014), with no statistically significant differences between the groups (BCVA: p = 0.139; spherical equivalent: p = 0.595). The trocar group demonstrated significantly greater improvement in astigmatism at both 1 month and 6 months (p = 0.046, p = 0.048), as well as in IOL astigmatism at 6 months (p = 0.049). Complication rates did not significantly differ between the groups.

Conclusions

Both modified Yamane techniques effectively improved BCVA and spherical equivalent. However, the trocar-cannula-based method yielded superior outcomes in astigmatism correction, suggesting a potential advantage in postoperative refractive stability.

Zitieren

APA

Jun, H., Cho, A., Sohn, J., & Cheong, H. (2026). Comparison of Surgical Outcomes Between Two Modified Yamane Techniques of Scleral Fixation of Intraocular Lenses. Journal of the Korean Ophthalmological Society, 67(4), 118-130. https://doi.org/10.3341/jkos.2026.67.4.118

Vancouver

Jun H, Cho A, Sohn J, Cheong H. Comparison of Surgical Outcomes Between Two Modified Yamane Techniques of Scleral Fixation of Intraocular Lenses. Journal of the Korean Ophthalmological Society. 2026;67(4):118-130. doi:10.3341/jkos.2026.67.4.118

BibTeX
@article{Jun2026,
  author = {Jun, Hyewon and Cho, Ahran and Sohn, Joonhong and Cheong, Heeyoung},
  title = {Comparison of Surgical Outcomes Between Two Modified Yamane Techniques of Scleral Fixation of Intraocular Lenses},
  journal = {Journal of the Korean Ophthalmological Society},
  year = {2026},
  volume = {67},
  number = {4},
  pages = {118--130},
  doi = {10.3341/jkos.2026.67.4.118}
}
Kostenlos starten →