Comparison of the Gas-Tank and Disposable-Gas Methods for Intraocular Perfluoropropane (C3F8) Tamponade in Vitrectomy
Journal of the Korean Ophthalmological Society · 15.03.2026 · 67 (3) · 73-78
DOI: 10.3341/jkos.2026.67.3.73 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of the Korean Ophthalmological Society, erschienen am 15.03.2026. Verfasst von Seoung Hyun An und 1 weiteren Autor:innen. Die Arbeit nennt 13 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0). Gefördert von: Dong-A University.
Abstract (Originalsprache)
Purpose
To compare the efficacy of the gas-tank method with that of the disposable-gas method in delivering intraocular perfluoropropane (C3F8) tamponade during vitrectomy.
Methods
This retrospective study included patients who underwent vitrectomy with C3F8 gas tamponade for retinal detachment between January 2014 and November 2023. In total, 152 patients were categorized into the gas-tank (47 patients) and disposable-gas (105 patients) groups. It was assumed that the gas reached its maximum intraocular volume at 72 h post-injection. The half-life and residual duration of the gas were calculated based on the assumption that the logit-transformed gas volume followed a linear decay. These parameters, along with intraocular pressure (IOP) measurements at postoperative day 1, day 3, week 1, month 1, and month 2, were compared between the two groups.
Results
The mean half-life of C3F8 gas was significantly longer in the disposable-gas group (29.10 days) compared to the gas-tank group (25.68 days) (p = 0.000). The residual duration of the gas was also significantly longer in the disposable-gas group (55.34 days, p = 0.000). Furthermore, the variance in half-life was notably smaller in the disposable-gas group (17.80) than in the gas-tank group (34.74), indicating greater consistency. No statistically significant differences in IOP were observed between the two groups at any postoperative time point.
Conclusions
Vitrectomy using disposable C3F8 gas for retinal detachment is an effective surgical technique that provides consistent and accurate intraocular gas concentrations.
Förderung
- Dong-A University
Zitieren
APA
An, S. H., & Jeong, W. J. (2026). Comparison of the Gas-Tank and Disposable-Gas Methods for Intraocular Perfluoropropane (C3F8) Tamponade in Vitrectomy. Journal of the Korean Ophthalmological Society, 67(3), 73-78. https://doi.org/10.3341/jkos.2026.67.3.73
Vancouver
An SH, Jeong WJ. Comparison of the Gas-Tank and Disposable-Gas Methods for Intraocular Perfluoropropane (C3F8) Tamponade in Vitrectomy. Journal of the Korean Ophthalmological Society. 2026;67(3):73-78. doi:10.3341/jkos.2026.67.3.73
BibTeX
@article{An2026,
author = {An, Seoung Hyun and Jeong, Woo Jin},
title = {Comparison of the Gas-Tank and Disposable-Gas Methods for Intraocular Perfluoropropane (C3F8) Tamponade in Vitrectomy},
journal = {Journal of the Korean Ophthalmological Society},
year = {2026},
volume = {67},
number = {3},
pages = {73--78},
doi = {10.3341/jkos.2026.67.3.73}
}
EUVIMED