EUVIMEDEUVIMED entdecken
Open Access · CC BY-NC 4.0

The Effectiveness of Glacial Acetic Acid and 95% Alcohol in Lysing Blood-Contaminated Liquid-Based Cervical Cytology Specimens

I Putu Sindhunata Upadhana, Fitria Diniah Janah Sayekti

Indonesian Journal of Cancer · 30.06.2026 · 20 (2) · 202-209

DOI: 10.33371/ijoc.v20i2.1475 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Indonesian Journal of Cancer, online erschienen am 30.06.2026. Verfasst von I Putu Sindhunata Upadhana und 1 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Liquid-based cervical cytology is a monolayer slide preparation technique that enhances the accuracy of conventional Pap smears. Blood contamination (erythrocytes) is one of the most common causes of inadequate liquid-based cervical cytology samples. Therefore, alternative methods and materials are necessary to improve the adequacy of blood contaminated liquid-based cervical cytology samples. This study aims to evaluate the effectiveness of a 95% alcohol and glacial acetic acid combination in enhancing the adequacy of blood-contaminated liquid-based cervical cytology samples.

Methods

A total of 30 samples were included in this study, with patients aged between 21 and 59 years. The samples were divided into two groups based on the ratio of 95% alcohol to glacial acetic acid, specifically 4:1 and 3:2. The study utilized an experimental design, wherein sample lysis was carried out using these two reagent combinations. The adequacy of the samples was evaluated microscopically both prior to and following the lysis process. Statistical analysis was performed using the Wilcoxon Signed-Rank Test and the Mann-Whitney U Test.

Results

The results demonstrated that the 95% alcohol and glacial acetic acid combination effectively improved sample adequacy, with the 3:2 ratio yielding a more significant improvement (80%) compared to the 4:1 ratio (60%). The p-values from the Wilcoxon Signed Rank Test were 0.003 for the 4:1 ratio and < 0.001 for the 3:2 ratio, indicating a significant difference between pre-lysis and post-lysis adequacy. However, the Mann-Whitney U test showed no significant difference between the two concentration ratios (p = 0.240).

Conclusions

The combination of 95% alcohol and glacial acetic acid is an effective alternative for enhancing the adequacy of blood-contaminated liquid-based cervical cytology samples, with the 3:2 ratio providing optimal results.

Zitieren

APA

Upadhana, I. P. S., & Sayekti, F. D. J. (2026). The Effectiveness of Glacial Acetic Acid and 95% Alcohol in Lysing Blood-Contaminated Liquid-Based Cervical Cytology Specimens. Indonesian Journal of Cancer, 20(2), 202-209. https://doi.org/10.33371/ijoc.v20i2.1475

Vancouver

Upadhana IPS, Sayekti FDJ. The Effectiveness of Glacial Acetic Acid and 95% Alcohol in Lysing Blood-Contaminated Liquid-Based Cervical Cytology Specimens. Indonesian Journal of Cancer. 2026;20(2):202-209. doi:10.33371/ijoc.v20i2.1475

BibTeX
@article{Upadhana2026,
  author = {Upadhana, I Putu Sindhunata and Sayekti, Fitria Diniah Janah},
  title = {The Effectiveness of Glacial Acetic Acid and 95% Alcohol in Lysing Blood-Contaminated Liquid-Based Cervical Cytology Specimens},
  journal = {Indonesian Journal of Cancer},
  year = {2026},
  volume = {20},
  number = {2},
  pages = {202--209},
  doi = {10.33371/ijoc.v20i2.1475}
}
Kostenlos starten →