Diagnostic Accuracy of Diffusion Weighted MR Imaging for Assessment of Myometrial Invasion and Lymph Node Metastasis In Endometrial Carcinoma
Bangladesh Journal of Radiology and Imaging · 08.06.2026 · 32 (2) · 112-123
DOI: 10.3329/bjri.v32i2.90617 ↗Kurz gefasst
Fachartikel in der Zeitschrift Bangladesh Journal of Radiology and Imaging, online erschienen am 08.06.2026. Verfasst von Rehana Parvin Ruma und 7 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY-NC 4.0).
Abstract (Originalsprache)
Background
Endometrial carcinoma is one of the most common gynecologic malignancy and main prognostic factors are depth of myometrial invasion & lymph node metastasis. Diffusion Weighted MR Imaging at high b value enhances natural contrast between tumor & background normal tissues.
Objective
To evaluate the accuracy of Diffusion Weighted MRI in assessment of myometrial invasion and lymph node metastasis in endometrial cancer. Methodology: 30 patients of biopsy-proven endometrial carcinoma was enrolled in this cross-sectional study in the Department of Radiology and Imaging, BSMMU, Dhaka, from March’2021 to February’2023. DW MRI (b-value= 50, 400 and 800 s/mm2) and corresponding ADC map findings were evaluated for presence of myometrial invasion and lymph node metastasis correlating with anatomical T1WI and T2WI in 3.0 Tesla machine taking histopathology as gold standard.
Results
Mean age was 60.8±7.2 years with postmenopausal bleeding being the major (76.7%) presenting complaint. Majority (60%) had < 6 months of symptom duration with minimum being 1 month. According to the histological subtype, 70% had endometrioid carcinoma and 26.7 % had serous adenocarcinoma and 3.3% had clear cell carcinoma. In endometrial carcinoma lesions, mean (+ standard deviation) ADC value was (0.719 + 0.601 × 10-3 mm2/s). Sensitivity, specificity, accuracy, positive predictive value and negative predictive value of Diffusion Weighted MRI in determining superficial and deep myometrial invasion were 89.5%, 90%, 90%, 94.45%, 83.35% and 90.9%, 89.5%, 90%, 83.3% & 94.4% respectively. Among 06(20%) patients having lymph node metastasis, 05(83.3%) had deep myometrial invasion and 01(16.7%) had superficial myometrial invasion. In our study, sensitivity, specificity, accuracy, positive predictive value and negative predictive value of Diffusion Weighted MRI in determining lymph node metastasis were 83.3%, 95.8%, 93.3%, 83.3 % and 95.8%.
Conclusion
Diffusion Weighted MR Imaging is very accurate and highly specific advanced quantitative tool for assessment of myometrial invasion and lymph node metastasis in the patients of endometrial carcinoma. BJRI, 2024; VOL. 32(2): 112-123
Zitieren
APA
Ruma, R. P., Shirin, M., Kamal, M. H. M., Sharmin, S., Alam, F., Liza, K. N., Rawli, M. H., & Sabah, J. (2026). Diagnostic Accuracy of Diffusion Weighted MR Imaging for Assessment of Myometrial Invasion and Lymph Node Metastasis In Endometrial Carcinoma. Bangladesh Journal of Radiology and Imaging, 32(2), 112-123. https://doi.org/10.3329/bjri.v32i2.90617
Vancouver
Ruma RP, Shirin M, Kamal MHM, Sharmin S, Alam F, Liza KN, et al. Diagnostic Accuracy of Diffusion Weighted MR Imaging for Assessment of Myometrial Invasion and Lymph Node Metastasis In Endometrial Carcinoma. Bangladesh Journal of Radiology and Imaging. 2026;32(2):112-123. doi:10.3329/bjri.v32i2.90617
BibTeX
@article{Ruma2026,
author = {Ruma, Rehana Parvin and Shirin, Mahbuba and Kamal, Mahmud Hasan Mostofa and Sharmin, Shohaila and Alam, Farzana and Liza, Kamrun Naher and Rawli, Marmain Hamid and Sabah, Jeenat},
title = {Diagnostic Accuracy of Diffusion Weighted MR Imaging for Assessment of Myometrial Invasion and Lymph Node Metastasis In Endometrial Carcinoma},
journal = {Bangladesh Journal of Radiology and Imaging},
year = {2026},
volume = {32},
number = {2},
pages = {112--123},
doi = {10.3329/bjri.v32i2.90617}
}
EUVIMED