EUVIMEDEUVIMED entdecken
Crossref

Diagnostic Accuracy of [99mTc] Pertechnetate Scintigraphy Among Patients with Suspected Meckel's Diverticulum – One-Year Experience in NINMAS

Afroja Sultana, Nasreen Sultana, M M Ruhul Amin, Shimul Sarkar, Shamsun Nahar Bailey, A K M Fazlul Bari

Bangladesh Journal of Nuclear Medicine · 19.05.2026 · 28 (2) · 329-335

DOI: 10.3329/bjnm.v28i2.89149 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Bangladesh Journal of Nuclear Medicine, online erschienen am 19.05.2026. Verfasst von Afroja Sultana und 5 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

The reported accuracy of pertechnetate scintigraphy (Meckel scan) for evaluating children with Meckel's diverticulum has steadily increased since its introduction into clinical practice in 1970. In our study, we retrospectively analyze the accuracy of Tc-99 m pertechnetate scintigraphy in NINMAS over 01 year.

Objective

This study aimed to evaluate the accuracy of pertechnetate scintigraphy performed at the National Institute of Nuclear Medicine & Allied Sciences (NINMAS) in pediatric patients with suspected Meckel's Diverticulum.

Methods

A retrospective study was conducted of 60 pediatric patients who presented with symptoms suggestive of MD and underwent 99mTc-pertechnetate scintigraphy at NINMAS over a 1-year period. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and overall diagnostic accuracy were calculated by comparing scintigraphic results with surgical and histopathological findings.

Result

Six patients were diagnosed with MD on 99mTc-pertechnetate scintigraphy, all confirmed histopathologically as true positives. Among 54 patients with negative scans, one was a false negative, and 53 were confirmed as true negatives through clinical, imaging, endoscopic, and laparoscopic evaluation. Accordingly, 99mTc-pertechnetate scintigraphy showed a sensitivity of 85.7% (6/7), specificity of 100.0% (53/53), positive predictive value of 100.0% (6/6), negative predictive value of 98.1% (53/54), and overall diagnostic accuracy of 98.3% (59/60) for MD. Receiver operating characteristic analysis revealed an area under the curve of 0.929 (standard error, 0.079; p < 0.001; 95% confidence interval, 0.775–1.082), indicating excellent diagnostic performance.

Conclusion

We find that Meckel scanning is a non-invasive procedure with low radiation exposure. It is a highly specific and accurate method for diagnosing MD in pediatric patients. Bangladesh J. Nuclear Med. 28(2): 329-335, July 2025

Zitieren

APA

Sultana, A., Sultana, N., Amin, M. M. R., Sarkar, S., Bailey, S. N., & Bari, A. K. M. F. (2026). Diagnostic Accuracy of [99mTc] Pertechnetate Scintigraphy Among Patients with Suspected Meckel's Diverticulum – One-Year Experience in NINMAS. Bangladesh Journal of Nuclear Medicine, 28(2), 329-335. https://doi.org/10.3329/bjnm.v28i2.89149

Vancouver

Sultana A, Sultana N, Amin MMR, Sarkar S, Bailey SN, Bari AKMF. Diagnostic Accuracy of [99mTc] Pertechnetate Scintigraphy Among Patients with Suspected Meckel's Diverticulum – One-Year Experience in NINMAS. Bangladesh Journal of Nuclear Medicine. 2026;28(2):329-335. doi:10.3329/bjnm.v28i2.89149

BibTeX
@article{Sultana2026,
  author = {Sultana, Afroja and Sultana, Nasreen and Amin, M M Ruhul and Sarkar, Shimul and Bailey, Shamsun Nahar and Bari, A K M Fazlul},
  title = {Diagnostic Accuracy of [99mTc] Pertechnetate Scintigraphy Among Patients with Suspected Meckel's Diverticulum – One-Year Experience in NINMAS},
  journal = {Bangladesh Journal of Nuclear Medicine},
  year = {2026},
  volume = {28},
  number = {2},
  pages = {329--335},
  doi = {10.3329/bjnm.v28i2.89149}
}
Kostenlos starten →