Abstract (Originalsprache)

Background

Carotid-cavernous fistula (CCF) and cavernous sinus dural arteriovenous fistula (dAVF) often present with ocular symptoms and may increase intraocular pressure (IOP). Cerebral angiography is the reference standard; however, noninvasive tools are needed to support diagnostic triage and treatment decision-making.

Objectives

To evaluate the diagnostic performance of superior ophthalmic vein (SOV) Doppler ultrasonography (DUS) for CCF/cavernous dAVF, to compare its performance with magnetic resonance angiography (MRA), and to assess the relationship between Doppler parameters and elevated IOP.

Methods

This retrospective diagnostic accuracy study included 67 eyes from 51 patients who underwent SOV DUS and cerebral digital subtraction angiography for suspected CCF/cavernous dAVF. Analyses were performed at the eye level. Diagnostic performance of DUS, MRA, and an either-positive combined strategy was calculated using cerebral angiography as the reference standard. Doppler parameters, clinical features, and IOP were analyzed, and receiver operating characteristic analysis was used to evaluate the ability of the resistive index (RI) to identify elevated IOP (≥ 20 mmHg).

Results

Cerebral angiography confirmed fistulas in 59/67 eyes (88.1%). DUS had a sensitivity of 72.9% (95% CI, 60.4%-82.6%) and specificity of 75.0% (95% CI, 40.9%-92.9%), whereas MRA had a sensitivity of 79.7% (95% CI, 67.7%-88.0%) and specificity of 87.5% (95% CI, 52.9%-97.8%). The combined DUS-or-MRA strategy increased sensitivity to 81.4% (95% CI, 69.6%-89.3%). RI showed limited discrimination for elevated IOP, with an area under the curve of 0.65 (95% CI, 0.46-0.79). At an RI cutoff of 0.62, sensitivity was 46.4% and specificity was 84.2%.

Conclusions

SOV DUS demonstrated moderate diagnostic performance for CCF/cavernous dAVF and may complement MRA in clinical triage. However, a negative DUS finding does not exclude the condition. RI should be interpreted as a supportive Doppler parameter rather than a standalone marker of elevated IOP.

Zitieren

APA

Apirakkan, M., Krisem, M., & Chanthanaphak, E. (2026). [2026-08-11] Diagnostic Performance of Superior Ophthalmic Vein Doppler Ultrasonography for Carotid-Cavernous Fistula and Cavernous Sinus Dural Arteriovenous Fistula. Research Medical Journal, e280317. https://doi.org/10.33165/rmj.2027.e280317

Vancouver

Apirakkan M, Krisem M, Chanthanaphak E. [2026-08-11] Diagnostic Performance of Superior Ophthalmic Vein Doppler Ultrasonography for Carotid-Cavernous Fistula and Cavernous Sinus Dural Arteriovenous Fistula. Research Medical Journal. 2026:e280317. doi:10.33165/rmj.2027.e280317

BibTeX
@article{Apirakkan2026,
  author = {Apirakkan, Mungkorn and Krisem, Massupa and Chanthanaphak, Ekachat},
  title = {[2026-08-11] Diagnostic Performance of Superior Ophthalmic Vein Doppler Ultrasonography for Carotid-Cavernous Fistula and Cavernous Sinus Dural Arteriovenous Fistula},
  journal = {Research Medical Journal},
  year = {2026},
  pages = {e280317},
  doi = {10.33165/rmj.2027.e280317}
}
Kostenlos starten →