EUVIMEDEUVIMED entdecken
Open Access · CC BY 4.0

Equalization of the Thai Digits-in-Noise Test: A Study on Young Adults With Normal Hearing Sensitivities

Sittiprapa Isarangura, Anatta Sereewattanakarn, Panyawee Dangsawasd, Pichaya Amaraphirakkhit, Samitanan Temworapanya, Somjin Chindavijak, Cas Smits, Carolina Der, Rattinan Tiravanichkul

Research Medical Journal · 20.03.2026 · e276573

DOI: 10.33165/rmj.2027.e276573 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Research Medical Journal, online erschienen am 20.03.2026. Verfasst von Sittiprapa Isarangura und 8 weiteren Autor:innen. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0).

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

By the year 2050, nearly 2.5 billion individuals globally will experience some degree of hearing loss. To facilitate its systematic detection and timely intervention, it is imperative to develop a Thai digits-in-noise (DIN) test for efficient hearing screening.

Objectives

To equalize the intelligibility of recorded Thai digits in the DIN test, ensuring consistent speech perception in noise.

Methods

Twenty-five normally hearing young adults participated in this study (mean [SD] age, 21.68 [1.11] years). Thai digits from 0 to 9 were recorded by a female native speaker, and the best recordings were selected for the experiment. Speech-shaped noise was generated to match the long-term average spectrum of all digits. A custom MATLAB script was used to present digit triplet combinations at fixed signal-to-noise ratios from -20 to -2 dB in 2 dB steps. Antiphasic stimuli were delivered dichotically through insert earphones, and participants responded via a keypad. Speech reception thresholds (SRTs) for each digit were calculated to assess intelligibility. A repeated-measure ANOVA was used to compare the SRTs of all digits.

Results

The average SRT for each digit exhibited slight variability, ranging from -18.1 dB (number 4) to -10.8 dB (number 2). The overall mean SRT across all digits was -14.7 dB. Significant differences in intelligibility were found across the Thai digits. Intensity adjustments were applied to digits, resulting in perceptual equalization with no significant differences post-adjustment.

Conclusions

Variability in digit intelligibility reflects acoustic differences inherent in the Thai language. The equalized Thai digits demonstrated consistent intelligibility, so they are suitable for use in speech-in-noise testing among Thai speakers, supporting clinical and research applications.

Zitieren

APA

Isarangura, S., Sereewattanakarn, A., Dangsawasd, P., Amaraphirakkhit, P., Temworapanya, S., Chindavijak, S., Smits, C., Der, C., & Tiravanichkul, R. (2026). Equalization of the Thai Digits-in-Noise Test: A Study on Young Adults With Normal Hearing Sensitivities. Research Medical Journal, e276573. https://doi.org/10.33165/rmj.2027.e276573

Vancouver

Isarangura S, Sereewattanakarn A, Dangsawasd P, Amaraphirakkhit P, Temworapanya S, Chindavijak S, et al. Equalization of the Thai Digits-in-Noise Test: A Study on Young Adults With Normal Hearing Sensitivities. Research Medical Journal. 2026:e276573. doi:10.33165/rmj.2027.e276573

BibTeX
@article{Isarangura2026,
  author = {Isarangura, Sittiprapa and Sereewattanakarn, Anatta and Dangsawasd, Panyawee and Amaraphirakkhit, Pichaya and Temworapanya, Samitanan and Chindavijak, Somjin and Smits, Cas and Der, Carolina and Tiravanichkul, Rattinan},
  title = {Equalization of the Thai Digits-in-Noise Test: A Study on Young Adults With Normal Hearing Sensitivities},
  journal = {Research Medical Journal},
  year = {2026},
  pages = {e276573},
  doi = {10.33165/rmj.2027.e276573}
}
Kostenlos starten →