EUVIMEDEUVIMED entdecken
Crossref

Comparing the Manual Liquid-Based Cytology with the Conventional Method in Bronchoaleolar Lavage Aspiration(Bal)/Bronchial Wash Fluids

Dayal Singh Bisht, Sanjukta .

Medical & Clinical Research · 30.07.2026 · 11 (07) · 01-07

DOI: 10.33140/mcr.11.07.01 ↗

Kurz gefasst

Fachartikel in der Zeitschrift Medical & Clinical Research, online erschienen am 30.07.2026. Verfasst von Dayal Singh Bisht und 1 weiteren Autor:innen.

AbstractBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

The technique of Liquid-Based Cytology, is the advanced methods of preparing cytology specimen, has surpassed conventional pap smears because it has enhanced fixation, minimized interference, and reliable cell transfer. In LBC, samples are gathered by completely immersing the sampling device in a vial filled with a preservative solution, which facilitates the concurrent preservation and fixation of cells, in contrast to traditional smears where the sample is applied to a glass slide and fixed subsequently. Currently, there are two primary methods for liquid preparation - ThinPrep and SurePath. In our research, the goal was to compare the manual liquid-based cytology with the conventional method in bronchoalveolar lavageaspiration (BAL)/bronchial wash fluids.

Aim

The aim was to compare the manual liquid-based cytology with the conventional method in bronchoalveolar lavage aspiration (BAL) /bronchial wash fluids. Material and Methods: A total of 100 Brochoalveolar lavage aspiration samples were analyzed in this prospective investigation utilizing conventional method preparations and manual liquid-based cytology. Cellularity, background, cellular preservation, and nuclear preservation were evaluated in both manual liquid-based cytology smears and direct smears. A cytopathologist independently examined the slides. For the purpose of statistical evaluation, the Chai-square test was utilized to determine the p-value and to assess the histopathological correlation.

Result

The cellularity observed in MLBC and conventional smears is similar, but the MLBC approach improves the evaluation of cell morphology by reducing nucleus overlap, haemorrhage, and necrosis. The recorded P value was below 0.05, which is considered statistically significant. The sensitivity rates were 18.9% for CC and 34.5% for LBC, respectively, while the specificity for both methods was 42.7% and 47.5%. Consequently, LBC demonstrated a slightly superior sensitivity in this analysis. Likewise, the negative predictive value showed a slight enhancement with LBC technology (55.1% for LBC compared to 50.0% for CC). The positive predictive values were 100% for LBC and 55.6% for CC across both techniques.

Conclusion

In contrast to traditional BAL fluid methods, the MLBC preparation in BAL aspiration fluid is safe, straightforward, and quick, potentially offering significant diagnostic advantages; however, utilizing both CS and MLBC preparations is advised for enhanced diagnostic outcomes.

Zitieren

APA

Bisht, D. S., & ., S. (2026). Comparing the Manual Liquid-Based Cytology with the Conventional Method in Bronchoaleolar Lavage Aspiration(Bal)/Bronchial Wash Fluids. Medical & Clinical Research, 11(07), 01-07. https://doi.org/10.33140/mcr.11.07.01

Vancouver

Bisht DS, . S. Comparing the Manual Liquid-Based Cytology with the Conventional Method in Bronchoaleolar Lavage Aspiration(Bal)/Bronchial Wash Fluids. Medical & Clinical Research. 2026;11(07):01-07. doi:10.33140/mcr.11.07.01

BibTeX
@article{Bisht2026,
  author = {Bisht, Dayal Singh and ., Sanjukta},
  title = {Comparing the Manual Liquid-Based Cytology with the Conventional Method in Bronchoaleolar Lavage Aspiration(Bal)/Bronchial Wash Fluids},
  journal = {Medical & Clinical Research},
  year = {2026},
  volume = {11},
  number = {07},
  pages = {01--07},
  doi = {10.33140/mcr.11.07.01}
}
Kostenlos starten →