Retrograde Looping of Peripherally Inserted Central Venous Catheter
Journal of Anesthesia & Pain Medicine · 2016
DOI: 10.33140/japm.01.01.08 ↗Kurz gefasst
Fachartikel in der Zeitschrift Journal of Anesthesia & Pain Medicine, 2016.
Abstract (Originalsprache)
An 80 kg 29-yr-old ASA class1 male patient was diagnosed to have carcinoma of right buccal mucosa and was posted for whole length excision of the lesion and pectoralis major myocutaneous (PMMC) flap reconstruction. His systemic examination and routine investigations were within normal limits. He had a short neck with restricted mouth opening. In the operation room all routine monitors were attached and an 18G IV cannula could be secured only after 6 attempts. After induction of GA we cannulated the left basalic vein with a 16G peripherally inserted central-venous catheter (PICC) (Cavafix® B. Braun, Melsungen AG) keeping arm at 45˚ abduction, turning the head to left side and applying pressure over left supraclavicular fossa. Due to the nature of surgery we did not cannulate the right side central veins. After confirming back flow of blood through the PICC, it was fixed at 45cm.
Zitieren
APA
(2016). Retrograde Looping of Peripherally Inserted Central Venous Catheter. Journal of Anesthesia & Pain Medicine. https://doi.org/10.33140/japm.01.01.08