EUVIMEDEUVIMED entdecken
Randomisierte kontrollierte StudieMultizentrische StudieOpen Access · CC BY 4.0

BioImpedance Spectroscopy to maintain Renal Output: the BISTRO randomised controlled trial

Simon J Davies iD, David Coyle iD, Elizabeth Lindley iD, David Keane iD, John Belcher iD, Fergus Caskey iD, Indranil Dasgupta iD, Andrew Davenport iD, Ken Farrington iD, Sandip Mitra iD, Paula Ormandy iD, Martin Wilkie iD und 5 weitere

Health Technology Assessment · 2025

DOI: 10.3310/rhon2378 ↗

Kurz gefasst

Randomisierte kontrollierte Studie in der Zeitschrift Health Technology Assessment, 2025. Verfasst von Simon J Davies und 16 weiteren Autor:innen. Beteiligte Einrichtung: School of Medicine, Keele University, Keele, Staffordshire, UK. Hauptthemen laut MEDLINE: Renal Dialysis, Dielectric Spectroscopy, Electric Impedance, Kidney Failure, Chronic. Die Arbeit wurde bisher 1-mal zitiert (Crossref) und nennt 40 Literaturangaben. Der Volltext ist frei zugänglich (Open Access, CC BY 4.0). Gefördert von: Health Technology Assessment programme.

AbstractSchlagwörterBibliografische AngabenZitierenVerwandte Studien

Abstract (Originalsprache)

Background

Fluid removal is a key component of dialysis treatment but, if excessive, can result in a faster decline in residual kidney function. Prescribing the optimal removal of fluid on dialysis to avoid this is therefore important. Bioimpedance spectroscopy, a bedside device that estimates tissue hydration, might improve this prescription, so reducing the rate of decline in kidney function and improving patient outcomes. We wished to establish the efficacy and cost-effectiveness of bioimpedance in pursuing this treatment strategy.

Methods

We undertook a multicentre, open-label, parallel, individually randomised controlled trial in incident haemodialysis patients, with clinicians and patients blinded to bioimpedance readings in the control group. Eligible patients had a urine output of > 500 ml/day or a glomerular filtration rate > 3 ml/minute/1.73 m 2 . Randomisation was 1 : 1 using a concealed automated computer-generated allocation system stratified by centre. Clinical assessments were made monthly for 3 months and then every 3 months for up to 24 months using a standardised proforma in both groups, supplemented in the intervention group by the bioimpedance estimate of the normally hydrated weight. The primary outcome was time to anuria; secondary outcomes were rate in decline of residual kidney function, blood pressure, dialysis-related symptoms (Integrated Palliative Care Outcome Scale-Renal), quality of life (EuroQol) and incremental cost per additional quality-adjusted life-year gained.

Results

Four hundred and thirty-nine patients were recruited and analysed from 34 United Kingdom centres. There were no between-group differences in cause-specific hazard rates of anuria, 0.751 (95% confidence interval 0.459 to 1.229) or subdistribution hazard rates 0.742 (95% confidence interval 0.453 to 1.215). Kidney function decline was slower than anticipated, pooled linear rates in year 1: −0.178 (95% confidence interval −0.196 to −0.159) ml/minute/1.73 m 2 /month; year 2: −0.061 (95% confidence interval −0.086 to −0.036) ml/minute/1.73 m 2 /month. Longitudinal blood pressure, symptoms and patient-reported outcomes did not differ by group. The intervention was associated with £382 (95% confidence interval −£3319 to £2556) lower average cost per patient (price year 2020) and 0.043 (95% confidence interval −0.019 to −0.105) more quality-adjusted life-years and no harm compared to control. A post hoc 5-year analysis found better survival with more residual kidney function at enrolment and at any time over the next 2 years.

Conclusion

The use of a standardised clinical protocol for fluid assessment to avoid excessive fluid removal is associated with excellent preservation of residual kidney function and better medium-term survival in this cohort. Bioimpedance measurements are not necessary to achieve this. Probability of the intervention being cost-effective was 76% and 83% at the willingness-to-pay thresholds of £20,000 and £30,000 per quality-adjusted life-year gained, respectively.

Limitations

The trial did not recruit to target (85%), and the number of primary outcomes was fewer than predicted. The trial was interrupted by coronavirus disease discovered in 2019, during which 193 (6.7%) fluid assessments and 276 (8.1%) kidney function measures but no primary outcomes were missed. Future work Associations between age, ethnicity and the decline in residual kidney function require further investigation. BioImpedance Spectroscopy to maintain Renal Output identified centre-level variation in practices related to fluid management in haemodialysis that require evaluation. Funding This synopsis presents independent research funded by the National Institute for Health and Care Research (NIHR) Health Technology Assessment programme as award number 14/216/01.

Schlagwörter

MeSH-Schlagwörter (MEDLINE)

Renal DialysisDielectric SpectroscopyElectric ImpedanceKidney Failure, ChronicHumansMaleFemaleAgedMiddle AgedCost-Benefit AnalysisGlomerular Filtration RateQuality of LifeAnuriaQuality-Adjusted Life YearsKidney

Stichwörter der Autor:innen

ANURIABLOOD PRESSURECLINICAL PROTOCOLSCOST-EFFECTIVENESS ANALYSISCOVID-19ETHNICITYGLOMERULAR FILTRATION RATEHEALTHCARE COSTSKIDNEYMULTICENTREPRACTICE PATTERNSQUALITY OF LIFEQUALITY-ADJUSTED LIFE-YEARSRANDOM ALLOCATIONRANDOMISED CONTROLLED TRIAL

Autor:innen und Institutionen

  • School of Medicine, Keele University, Keele, Staffordshire, UK.
  • NIHR Devices for Dignity, Sheffield Teaching Hospitals NHS Foundation Trust, Sheffield, UK.
  • Renal Medicine, Leeds Teaching Hospitals NHS Trust, Leeds, UK.
  • CÚRAM SFI Research Centre for Medical Devices, University of Galway, Galway, Ireland.
  • Population Health Sciences, University of Bristol, Bristol, UK.
  • Renal Medicine, University Hospitals Birmingham NHS Foundation Trust, Birmingham, UK.

ORCID-Profile: Simon J Davies, David Coyle, Elizabeth Lindley, David Keane, John Belcher, Fergus Caskey, Indranil Dasgupta, Andrew Davenport, Ken Farrington, Sandip Mitra, Paula Ormandy, Martin Wilkie, Jamie MacDonald, Mandana Zanganeh, Lazaros Andronis, Ivonne Solis-Trapala, Julius Sim

Förderung

  • Health Technology Assessment programme

Zitieren

APA

Davies, S. J., Coyle, D., Lindley, E., Keane, D., Belcher, J., Caskey, F., Dasgupta, I., Davenport, A., Farrington, K., Mitra, S., Ormandy, P., Wilkie, M., MacDonald, J., Zanganeh, M., Andronis, L., Solis-Trapala, I., & Sim, J. (2025). BioImpedance Spectroscopy to maintain Renal Output: the BISTRO randomised controlled trial. Health Technology Assessment. https://doi.org/10.3310/rhon2378

Vancouver

Davies SJ, Coyle D, Lindley E, Keane D, Belcher J, Caskey F, et al. BioImpedance Spectroscopy to maintain Renal Output: the BISTRO randomised controlled trial. Health Technology Assessment. 2025. doi:10.3310/rhon2378

BibTeX
@article{Davies2025,
  author = {Davies, Simon J and Coyle, David and Lindley, Elizabeth and Keane, David and Belcher, John and Caskey, Fergus and Dasgupta, Indranil and Davenport, Andrew and Farrington, Ken and Mitra, Sandip and Ormandy, Paula and Wilkie, Martin and MacDonald, Jamie and Zanganeh, Mandana and Andronis, Lazaros and Solis-Trapala, Ivonne and Sim, Julius},
  title = {BioImpedance Spectroscopy to maintain Renal Output: the BISTRO randomised controlled trial},
  journal = {Health Technology Assessment},
  year = {2025},
  doi = {10.3310/rhon2378}
}
Kostenlos starten →